Configuration and diagnostics software - Sensor Studio
Leuze electronic GmbH + Co. KG
BCL 8
48
9.6
Diagnosis
Figure 9.15:
Diagnosis
tab
On the
Diagnosis
tab, you can send online commands to the device (see chapter 11 "Online commands")
as well as display the read results and the device status.
Furthermore, buttons are available for the following functions:
• Layout of the screen display
• Deleting and printing the screen content
• General terminal settings
9.7
Firmware Reload
With the
Firmware Reload
tool (
MAINTENANCE
tab), you can load a different firmware into the device.
Version
Requests device version information (see chapter 11.1.1
"General online commands", command "V").
You can use this command to check whether the communication
between PC and scanner is functional. If you do not receive an
acknowledgment, please check the interface connections or the
protocol.
Device Identification
Query of the serial number as well as the hardware and software
versions.
Reset
Carries out a software reset. The device is restarted and reinitial
-
ized, leaving it in the same state as when the operating voltage is
switched on.
Factory Default
Activates the device with the factory settings.
Activate Decoding
Deactivate Decoding
Activates/deactivates decoding.
Start Continuous Decoding
Stop Continuous Decoding
Starts/stops continuous decoding.
NOTE
You can find detailed information on the
Firmware Reload
tool in the information area of the
FIRMWARE RELOAD dialog box and in the
Sensor Studio
online help.