manualshive.com logo in svg
background image

 

NT-1202 
 

Quick Setup Guide   

This is 1D&2D plug and play model if you use a US keyboard. If you use other type of keyboard, plug 
the USB cable on your device , setup keyboard language before you use it. (refer to below Keyboard 
Language Type) after that the scanner can start to work. 

 

                     

                     

                               

 

If you want to do other configurations please refer to below programming barcodes.   

 

Barcode Programming   
 

Netum barcode scanners are factory programmed for common terminal and communications 
settings. If you need to change these settings, programming is accomplished by scanning the bar 
codes in this guide. An asterisk (*) next to an option indicates the default setting. 

 

Communication Mode 

 
USB -KBW   

When you connect the scanner to the Host via a USB connection, you can enable the USB-KBW 
feature by scanning the barcode below. It works on a Plug and Play basis and no driver is 
required. 

                                         

 

                                                        USB KBW* 
USB Serial Port   

If you connect scanner to the Host via a USB connection, the 

USB COM Port Emulation 

feature 

allows the Host to receive data in the way as a serial port does. 

 

                                                     

 

                                                                   

USB Serial Port

 

Содержание NT-1202

Страница 1: ... for common terminal and communications settings If you need to change these settings programming is accomplished by scanning the bar codes in this guide An asterisk next to an option indicates the default setting Communication Mode USB KBW When you connect the scanner to the Host via a USB connection you can enable the USB KBW feature by scanning the barcode below It works on a Plug and Play basi...

Страница 2: ...guage In order to let scanner upload the codes in a correct way you have to set the keyboard language For example If you use French Keyboard scan below barcode of French keyboard then scanner will upload barcodes according to France keyboard layout American Keyboard is set by default if you use a US keyboard you can skip this step America Keyboard Portugal Keyboard Franc Keyboard Spain Keyboard Ge...

Страница 3: ...ecified time will automatically trigger the next reading Continuous Mode Auto Sense Mode Under auto sense mode scanner detects the brightness of the surroundings Trigger reading when the brightness changes Reading success or reading time over a single reading time will end the reading Regardless of the last success or failure to read re enter the detection of the surrounding environment brightness...

Страница 4: ...sable CR LF CR TAB Beeper Volume To select a decode beep volume scan the appropriate bar code Low Medium High Mute To enable or disable close all prompt scan the appropriate bar code below Disable Enable ...

Страница 5: ... ID Character A code ID character identifies the code type of a scanned bar code This can be useful when decoding more than one code type The code ID character is inserted between the prefix character if selected and the decoded symbol Symbol Code ID Aim Code ID None Symbol Code ID refer to Symbol Code Identifiers Aim Code ID refer to AIM Code Identifiers ...

Страница 6: ...le Disable UPC E To enable or disable UPC E scan the appropriate bar code below Enable UPC E Disable UPC E Enable Disable EAN 8 To enable or disable EAN 8 scan the appropriate bar code below Enable EAN 8 Disable EAN 8 Enable Disable EAN 13 To enable or disable EAN 13 scan the appropriate bar code below Enable EAN 13 Disable EAN 13 ...

Страница 7: ... g UPC A 2 UPC E 2 EAN 13 2 EAN 13 5 The following options are available Ignore UPC EAN with Supplementals Do not read supplementals Scanner can only read the barcode no matter the barcode with supplementals or not Only read the barcode with supplementals The scan engine can only read the barcode with supplementals Auto read supplementals The scan engine can not only read the barcode with suppleme...

Страница 8: ...the symbol with or without the UPC E check digit Transmit UPC E Check Digit Do Not Transmit UPC E Check Digit Convert UPC E to UPC A Enable this parameter to convert UPC E zero suppressed decoded data to UPC A format before transmission After conversion data follows UPC A format and is affected by UPC A programming selections Convert UPC E to UPC A Scan DO NOT CONVERT UPC E TO UPC A to transmit UP...

Страница 9: ...nable Disable Code 39 To enable or disable Code 39 scan the appropriate bar code below Enable Code 39 Disable Code 39 Transmit Code 39 Check Digit Scan this symbol to transmit the check digit with the data Transmit Code 39 Check Digit Enable Scan this symbol to transmit data without the check digit Do Not Transmit Code 39 Check Digit Disable ...

Страница 10: ...ASCII cannot be enabled simultaneously If you get an error beep when enabling Code 39 Full ASCII disable Trioptic Code 39 and try again Code 93 Enable Disable Code 93 To enable or disable Code 93 scan the appropriate bar code below Enable Code 93 Disable Code 93 Code 11 Enable Disable Code 11 To enable or disable Code 11 scan the appropriate bar code below Enable Code 11 Disable Code 11 Transmit C...

Страница 11: ...ut the check digit Do Not Transmit I 2 of 5 Check Digit Disable Convert I 2 of 5 to EAN 13 This parameter converts a 14 character I 2 of 5 code into EAN 13 and transmits to the host as EAN 13 To accomplish this I 2 of 5 must be enabled one length must be set to 14 and the code must have a leading zero and a valid EAN 13 check digit Convert I 2 of 5 to EAN 13 Do Not Convert I 2 of 5 to EAN 13 Discr...

Страница 12: ...nsmit Check Character Disable Matrix 25 Transmit Check Character Codabar Enable Disable Codabar To enable or disable Codabar scan the appropriate bar code below Enable Codabar Disable Codabar MSI MSI PLESSEY Enable Disable MSI To enable or disable MSI scan the appropriate bar code below Enable MSI Disable MSI Transmit MSI Check Digit Scan this symbol to transmit the check digit with the data ...

Страница 13: ...an the appropriate bar code below Enable GS1 DataBar 14 Disable GS1 DataBar 14 Enable Disable GS1 DataBar Limited To enable or disable GS1 DataBar Limited scan the appropriate bar code below Enable GS1 DataBar Limited Disable GS1 DataBar Limited Enable Disable GS1 DataBar Expanded To enable or disable GS1 DataBar Expanded scan the appropriate bar code below Enable GS1 DataBar Expanded Disable GS1 ...

Страница 14: ...trix Enable DataMatrix Maxi Code Enable Disable Maxi Code To enable or disable Maxi Code scan the appropriate bar code below Disable MaxiCode Enable MaxiCode Prefix Suffix Values A prefix and or one or two suffixes can be appended to scan data for use in data editing To set these values scan a four digit number i e four bar codes that corresponds to ASCII values See the Table 4 3 and Numeric Bar C...

Страница 15: ...sion Format must be set Scan Prefix Scan Suffix 1 Scan Suffix 2 Scan Data Transmission Format To change the Scan Data Transmission Format scan one of the eight bar codes corresponding to the desired format Data As Is DATA SUFFIX 1 DATA SUFFIX2 DATA SUFFIX 1 SUFFIX 2 PREFIX DATA PREFIX DATA SUFFIX 1 ...

Страница 16: ... Down But if you scan Enable Functional Key Set after you scan the value 1004 you will get functional key set Ctrl D For more details please refer to Appendix 2 4 Appendix 1 Numeric Bar Codes For parameters requiring specific numeric values scan the appropriately numbered bar code s Numeric Bar Codes For parameters requiring specific numeric values scan the appropriately numbered bar code s 0 ...

Страница 17: ...1 2 3 4 5 ...

Страница 18: ...6 7 8 9 Example on how to set prefix and suffix Prefix Setting Step 1 scan prefix Scan Prefix ...

Страница 19: ...e the Table 4 3 and Numeric Bar Codes in appendix Step 3 i e if you want to add scan 1043 one by one 1 0 4 3 Step 4 Set Data Transmission Format PREFIX DATA Suffix Setting Step 1 scan suffix Scan Suffix 1 Step 2 and Step 3 same procedures like setting prefix Step 4 Set Data Transmission Format DATA SUFFIX 1 ...

Страница 20: ...r Equivalents Continued Scan Value Hex Value Full ASCLL Code 39 Encode Char Keystroke 1000 00h U CTRL 2 1001 01h A CTRL A 1002 02h B CTRL B 1003 03h C CTRL C 1004 04h D CTRL D 1005 05h E CTRL E 1006 06h F CTRL F 1007 07h G CTRL G 1008 08h H CTRL H 1009 09h I CTRL I 1010 0Ah J CTRL J 1011 0Bh K CTRL K 1012 0Ch L CTRL L 1013 0Dh M CTRL M 1014 0Eh N CTRL N 1015 0Fh O CTRL O 1016 10h P CTRL P 1017 11h...

Страница 21: ... 1Ah Z CTRL Z 1027 1Bh A CTRL 1028 1Ch B CTRL 1029 1Dh C CTRL 1030 1Eh D CTRL 6 1031 1Fh E CTRL 1032 20h Space Space 1033 21h A 1034 22h B 1035 23h C 1036 24h D 1037 25h E 1038 26h F 1039 27h G 1040 28h H 1041 29h I 1042 2Ah J 1043 2Bh K 1044 2Ch L 1045 2Dh 1046 2Eh 1047 2Fh 1048 30h 0 0 1049 31h 1 1 1050 32h 2 2 1051 33h 3 3 1052 34h 4 4 1053 35h 5 5 1054 36h 6 6 1055 37h 7 7 ...

Страница 22: ... 3Bh F 1060 3Ch G 1061 3Dh H 1062 3Eh I 1063 3Fh J 1064 40h V 1065 41h A A 1066 42h B B 1067 43h C C 1068 44h D D 1069 45h E E 1070 46h F F 1071 47h G G 1072 48h H H 1073 49h I I 1074 4Ah J J 1075 4Bh K K 1076 4Ch L L 1077 4Dh M M 1078 4Eh N N 1079 4Fh O O 1080 50h P P 1081 51h Q Q 1082 52h R R 1083 53h S S 1084 54h T T 1085 55h U U 1086 56h V V ...

Страница 23: ... 5Ah Z Z 1091 5Bh K 1092 5Ch I 1093 5Dh M 1094 5Eh N 1095 5Fh O _ 1096 60h W 1097 61h A a 1098 62h B b 1099 63h C c 1100 64h D d 1101 65h E e 1102 66h F f 1103 67h G g 1104 68h H h 1105 69h I i 1106 6Ah J j 1107 6Bh K k 1108 6Ch L l 1109 6Dh M m 1110 6Eh N n 1111 6Fh O o 1112 70h P p 1113 71h Q q 1114 72h R r 1115 73h S s 1116 74h T t 1117 75h U u ...

Страница 24: ...ents Continued Scan Value Hex Value Full ASCLL Code 39 Encode Char Keystroke 1118 76h V v 1119 77h W w 1120 78h X x 1121 79h Y y 1122 7Ah Z z 1123 7Bh P 1124 7Ch Q 1125 7Dh R 1126 7Eh S 1127 7Fh Undefined Symbol Code Identifiers ...

Страница 25: ...AIM Code Identifiers ...

Страница 26: ...Appendix 2 ...