Online commands
Leuze electronic GmbH + Co. KG
BCL 8
60
Acknowledge parameter message
Transfer parameters
Command
’PS’
Description
The command acknowledges the received message and delivers an
acknowledgment status which indicates whether the message was valid or
invalid.
Parameter
’PSx’
x
Status
'0' valid transmission
'1' invalid message
'2' invalid length of message
'3' invalid block check type
'4' invalid block check checksum
'5' invalid data length
'6' invalid message data
'7' invalid start address
'8' invalid parameter set
'9' invalid parameter set type
Command
’PT’
Description
The command transmits parameter data starting from the defined address
and stores them in an intermediate buffer. If the status indicates that further
messages follow, these are also stored in the intermediate buffer before they
are then stored under the corresponding parameter set type in the EEPROM.
The transmission can optionally occur with a block check test of the message
data.
Parameter
<BCC type> <PS type> <Status> <Start address> <Para0L> <Para0H>
[… <Para122L>][<BCC>]
Acknowledgment
’PSx’
x
Status
'0' valid transmission
'1' invalid message
'2' invalid length of message
'3' invalid block check type
'4' invalid block check checksum
'5' invalid data length
'6' invalid message data
'7' invalid start address
'8' invalid parameter set
'9' invalid parameter set type
Example
’PT03203305’
Address 33 (equal scans) is set to 5.
Save in RAM with reset (immediate acceptance of the change and temporary
storage)