Configuration and diagnostics software - Sensor Studio
Leuze electronic GmbH + Co. KG
BCL 8
43
9.5.3 Control tab
Figure 9.8:
Control
tab
Activation
Deactivation
Switching input 1
Function
See menu switching input
Auto-start after decoding
Autostart after decode
In this mode, the scanner reads via an internal trigger signal with
maximum performance.
Note: Up to 100 codes per second can be transmitted.
Command character
The standard online character for the trigger start is the ’+’ char
-
acter.
This character cannot be changed.
Decode delay time
After the time set here has passed, the scanner automatically
reactivates itself following a reading gate end (e.g. in combination
with "Autostart after decoding"). Is normally used for test
purposes.
Switching input 1
Function
See menu switching input
Immediately after the complete
decoding result is available
If the setting is activated, the read result is output immediately
after the bar code is decoded.
If the setting is deactivated, the read result is sent only after the
trigger signal is returned (= end of reading gate).
Command character
The standard online character for the trigger end is the ’-’ char
-
acter.
This character cannot be changed.
Time
If the code reader is activated, the reading gate is automatically
closed by the code reader after this preset time has elapsed (e.g.
for test purposes).
Scans without info
Following a successful read, the code reader waits for this
number of scans (sequential scans with no read result) before it
automatically deactivates itself.