Technical data
Leuze electronic GmbH + Co. KG
BCL 8
12
4
Technical data
4.1
General specifications BCL 8
Optical data
Light source
Laser diode
Laser class
1 acc. to IEC/EN 60825-1:2014 and U.S. 21 CFR 1040.10 with
Laser Notice No. 56
Wavelength
655nm
Scanning rate
M optics: 600 scans/s
N optics: 500 scans/s
Resolution
M optics: m = 0.150 … 0.500 mm / 6 … 20 mil
N optics: m = 0.127 … 0.400 mm / 5 … 16 mil
Beam deflection
Via rotating polygon wheel
Beam exit
Front, alternatively on the side with deflection mirror (105°)
Reading distance
See reading fields
Reading field opening
See reading fields
Code types
2/5 Interleaved, Code 39, Code 128, EAN 128, EAN/UPC, EAN
Addendum, Codabar, Pharma Code, Code 93
Software features
Selectable output format, autoConfig, autoReflAct, reference
code comparison, multiple read, real time decoding, adjustment
mode, control of switching input or switching output, etc.
Electrical data
Interface type
RS 232, freely configurable
Baud rate
4800 … 57600 Bd
Data formats
Data bits: 7, 8
Parity: none, even, odd
Stop bit: 1, 2
Protocols
Framing protocol with/without acknowledgment
Software handshake X ON / X OFF
Service interface
RS 232 with fixed data format,
9600Bd, 8 data bits, no parity, 1 stop bit
<STX> <data> <CR><LF>
Ports
1 switching input 5VDC
or
1 switching output 5 … 30V, 20mA
LEDs
1 device status
1 read status
Operating voltage
4.75 … 5.5VDC, protection class III - PELV
1)
(Protective Extra Low Voltage)
Current consumption
Max. 250 mA (2 W power supply unit recommended)
Mechanical data
Degree of protection
IP 67
Connection type
M12 connector, 5-pin, turnable or
Fixed cable, 2 m long, 5 x 0.25 mm
2
Weight
70g
Dimensions (H x W x D)
Front beam exit: 48 x 40.3 x 15 mm
Lateral beam exit: 48 x 58 x 17.4 mm
Housing
Metal (diecast zinc)
Environmental data
Ambient temp.
(operation/storage)
0°C … +40°C/-20°C … +60°C
Air humidity
Max. 90% rel. humidity, non-condensing
Vibration
IEC 60068-2-6, test Fc
Shock
IEC 60068-2-27, test Ea
Table 4.1:
Technical data