Configuration and diagnostics software - Sensor Studio
Leuze electronic GmbH + Co. KG
BCL 8
42
Figure 9.7: Properties dialog box (COMMON PROPERTIES)
Communication settings
(Output channel)
Select from one of the options listed.
Standard setting:
Host Interface
Code output only if the codes/labels
are different
(Output different result only)
If you select this setting, a read result is only output within a
reading gate opening if it is different to the previous read result.
When rack reading, for example, this is used to set that the codes
within adjacent samples are only output once.
Deletion of code output memory
(Difference memory timeout)
Selecting this setting deletes the difference memory after the
timeout time that can be set to the right of the checkbox has
elapsed.
After the timeout time has elapsed, a detected label is output a
second time even if it was already directly detected once and the
Output different result only
checkbox is selected.
The timeout time between the last reading and deletion of the
difference memory can be set from 100 ms to 5000 ms.