EtherNet/IP interface
Leuze electronic
AMS 358
i
76
TNT
35/7-2
4
V
Activation is via bit 8.
0 = dynamic output inactive
1 = the hardware output(s) is(are) set as defined in attribute 2
The outputs are dynamically set via 256
d
(256 = status message bits 7 to 2 are disre-
garded).
9.7.6
Class 104 Behavior in the case of error
Object class 104 = 68
H
Service:
• Get_Attribute_Single
• Set_Attribute_Single
9.7.6.1
Position value in the case of failure
Attribute 1
The attribute specifies which position is transmitted in the case of an error after the "error
delay time - position" elapses.
0 = last valid value
1 = value 0
9.7.6.2
Error delay - position status
Attribute 2
The attribute specifies whether the PLB status bit (implausible measurement value) is set
immediately or after the "error delay time - position" elapses.
0 = PLB status bit is set immediately
1 = PLB status bit is set with a delay
Path
Designation
Size
in bit
Data type
Default
(dec)
Min
(dec)
Max
(dec)
Access
Cl.
Inst.
Attr.
104
1
1
Position value in the case of
error
8
BYTE
1
0
1
Set
2
Suppress position status
8
BYTE
1
0
1
Set
3
Error delay (position)
8
BYTE
1
0
1
Set
4
Error delay time (position)
16
UINT
100
100
1.000
Set
5
Velocity in the case of
failure
8
BYTE
1
0
1
Set
6
Suppress velocity status
8
BYTE
1
0
1
Set
7
Error delay (velocity)
8
BYTE
1
0
1
Set
8
Error delay time (velocity)
16
UINT
200
200
1.000
Set