Diagnostics and troubleshooting
Leuze electronic
AMS 358
i
88
TNT
35/7-2
4
V
10.1.2
Diagnostics
The diagnostics function is activated by selecting the
Diagnostics
menu item. The ESC
button
deactivates the diagnostics function and clears the contents of the recordings.
The recorded diagnostic data are displayed in 2 fields. In the upper half of the display, status
messages of the AMS and the bar graph are displayed. The lower half contains information
that assists in a Leuze-internal evaluation.
Use the up/down buttons
to scroll in the bottom half between various displays. The
contents of the scrollable pages are intended solely for Leuze for internal evaluation.
The diagnostics have no influence on the communication to the host interface and can be
activated during operation of the AMS 358
i
.
10.1.3
Expanded diagnostics
The
Expanded diagnostics
menu item is used for Leuze-internal evaluation.
10.2
General causes of errors
The LEDs for PWR and Net are designed as bicolor LEDs. A change in color from red/green
and a static/flashing display facilitate further diagnostics.
After power ON, a test of the Power LED and Net LED is performed in the following sequence:
1.
LEDs off.
2.
LEDs are switched to green for approx. 0.25 s.
3.
LEDs are switched to red for approx. 0.25 s.
4.
LEDs off.
This is followed by the status display for the power LED (see chapter 9.3) and the Net LED.
ESC
IO1
LSR
PLB
IO2 TMP
ATT
ERR
Pos. current: --------
Pos. min.:
--------
Pos. max.:
--------