Fast commissioning / operating principle
11
AMS 358
i
Leuze electronic
3.2
Connecting the voltage supply
The laser measurement system is connected using M 12 connectors. The voltage supply is
connected via the
PWR
M 12 connection.
Detailed information can be found in chapter 7.
3.2.1
Connecting the EtherNet/IP network
The EtherNet/IP is connected via D-coded M 12 connectors for
BUS IN
and
BUS OUT
.
BUS IN and BUS OUT are coupled by means of an internal switch.
Detailed information can be found in chapter 7.
3.3
Display
Once the laser measurement system is supplied with voltage, the device status as well as
the measured position values can be read on the display. The display automatically switches
to the display of the measurement values.
Use the up/down buttons
to the left of the display to read and change a wide range
of data and parameters.
Depending on connected interface, the network address must be configured via the display.
Detailed information can be found in chapter 8.
3.4
AMS 358
i
on EtherNet/IP
Notice!
Prior to commissioning, the EDS file of the AMS 358
i
should be installed in the corresponding
control.
Commissioning on the EtherNet/IP is performed according to the following scheme:
1.
Activate parameter enabling
2.
Address assignment (manual or automatic via DHCP or BootP)
3.
Deactivate parameter enabling
4.
Configure the participant
5.
Transfer the data to the control
6.
Configuration of the config assembly, when doing so observe chapter 9.6 without fail
7.
Use explicit messaging services