EtherNet/IP interface
Leuze electronic
AMS 358
i
62
TNT
35/7-2
4
V
9.7.1.5
Status
Principle and primary monitoring of the device, of the network and of the configuration. The
entries are described by the scanner.
9.7.1.6
Serial number
For use in EtherNet, the serial number receives a serial number converted according to CIP.
CIP describes a special format for the serial number. After conversion to a CIP code, the
serial number is, as before, unique, but no longer corresponds in its resolution to the serial
number on the name plate.
9.7.1.7
Product name
This attribute contains a short designation of the product. Devices with the same product
code may have different "product names".
9.7.1.8
State
This attribute contains information about the current status of the AMS358i.
9.7.1.9
Configuration Consistency Value
In this attribute, an entry may occur upon change of a parameter. The function is not
supported by the AMS 358
i
. The default entry of 0 (zero) does not change.
9.7.1.10 Heartbeat Interval
The attribute sets a time interval in which a "heartbeat message" is sent by the AMS 358
i
.
The value is entered in seconds.
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
ext. device state
reserved
configured
reserved
owned
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
reserved
Major unrecov-
erable fault
Major recover-
able fault
Major unrecov-
erable fault
Major recover-
able fault