![Leuze electronic AMS 358i Скачать руководство пользователя страница 72](http://html1.mh-extra.com/html/leuze-electronic/ams-358i/ams-358i_manual_1883975072.webp)
EtherNet/IP interface
69
AMS 358
i
Leuze electronic
Notice!
Attribute 103 is toggled.
9.7.2.21 Direction of movement
Attribute 105
At a velocity > 100 mm/s, the attribute indicates the direction of movement.
0 = positive direction of movement
1 = negative direction of movement
The definition of the direction of movement is dependent on class 35, instance 1,
attribute 12:
• Positive counting direction:
Measurement values
increase
if the reflector moves away from the AMS 358
i
. In this
case, the positive direction = 0 in attribute 105.
• Count direction negative:
Measurement values
decrease
if the reflector moves away from the AMS 358
i
. In this
case, the positive direction = 1 in attribute 105.
9.7.2.22 Movement status
Attribute 106
The attribute indicates whether the absolute value is large enough (> 100 mm/s) to register
a movement.
0 = |cur. velocity| < 100 mm/s
1 = |cur. velocity| > 100 mm/s
9.7.2.23 Free resolution
Attribute 107
The free resolution refers to parameters 2048 and 2052 in attribute 15.
For parameter 2048, the entry is made in mm/1000; for parameter 2052, the entry is made
in inch/100,000.
Example:
For a free resolution of e.g., 0.875 mm, the value "875" must be entered for parameter 2048.
9.7.2.24 Offset
Attribute 108
Measurement value at the interface = measured di offset.
The attribute sets an offset to the measured value in the AMS 358
i
. The offset takes imme-
diate effect following instruction "set attribute single class1 instance1 attribute108".
Attr.
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
108
0
Offset value calculated from activated preset value (low byte)
1
Offset value calculated from activated preset value
2
Offset value calculated from activated preset value
3
Offset value calculated from activated preset value (high byte)