Commissioning
Torque control
Activating the operating mode
5
49
SW-HB 13.0002-EN EN 3.0
5.3.4
Activating the operating mode
For torque control, configure the command window as follows:
931e_226
The torque setpoint can be selected in A or Nm. Open the menu
Options
Display units
to
select the unit. The corresponding menus will then automatically use the selected unit.
Ifthetorqueis tobeselected inNm, thetorque constant,i.e. theconversion factorbetween
current and torque, must be known. The torque constant can be entered in the menu
Parameters
Device parameters
Motordata
.Usually,itcanalsobecalculated bymeans
of the nameplate data on the motor. For this, divide the rated torque by the rated current.
Note!
A torque constant of 0 Nm/A is impermissible, if ”Torque in Nm” has been
activated.
efesotomasyon.com - Lenze