Commissioning
Important notes
5
25
SW-HB 13.0002-EN EN 3.0
5
Commissioning
5.1
Important notes
Beforeswitching onthesupplyvoltageforthe931Eservopositioning controllerforthefirst
time, check the following connections for correctness and completeness:
ƒ
Motor cable and synchronous motor connection (X3)
ƒ
Feedback system connection (X7/X8)
ƒ
Digital I/O connection (e.g. DIN9 of plug connector X5)
ƒ
Connection of the voltage supply for control section and power stage (X2)
ƒ
Connection of the serial communication cable (X1)
For additional information, please see the Controller Manual (GHB931E) or the Mounting
Instructions. For parametersetting, theserial interfaceof the931E (X1) must beconnected
with a free COM port on your notebook / PC.
Stop!
Please carefully check the wiring and the supply voltages selected, before
switching on the voltage supply for the first time!
ƒ
Malfunctions are most often due to wiring faults.
ƒ
Wiring faults or an excessive operating voltage may cause damage to the
controller!