© Copyright Lenovo 2018
545
Chapter 39. sFLOW
The
NE2552E
supports
sFlow
technology
for
monitoring
traffic
in
data
networks.
The
switch
includes
an
embedded
sFlow
agent
which
can
be
configured
to
sample
network
traffic
and
provide
continuous
monitoring
information
of
IPv4
traffic
to
a
central
sFlow
analyzer.
The
switch
is
responsible
only
for
forwarding
sFlow
information.
A
separate
sFlow
analyzer
is
required
elsewhere
on
the
network
in
order
to
interpret
sFlow
data.
Note:
Lenovo
ENOS
8.4
does
not
support
IPv6
for
sFLOW.
sFlow Statistical Counters
The
NE2552E
can
be
configured
to
send
network
statistics
to
an
sFlow
analyzer
at
regular
intervals.
For
each
port,
a
polling
interval
of
5
to
60
seconds
can
be
configured,
or
0
(the
default)
to
disable
this
feature.
When
polling
is
enabled,
at
the
end
of
each
configured
polling
interval,
the
NE2552E
reports
general
port
statistics
and
port
Ethernet
statistics.
sFlow Network Sampling
In
addition
to
statistical
counters,
the
NE2552E
can
be
configured
to
collect
periodic
samples
of
the
traffic
data
received
on
each
port.
For
each
sample,
128
bytes
are
copied,
UDP
‐
encapsulated,
and
sent
to
the
configured
sFlow
analyzer.
For
each
port,
the
sFlow
sampling
rate
can
be
configured
to
occur
once
each
256
to
65536
packets,
or
0
to
disable
(the
default).
A
sampling
rate
of
256
means
that
one
sample
will
be
taken
for
approximately
every
256
packets
received
on
the
port.
The
sampling
rate
is
statistical,
however.
It
is
possible
to
have
slightly
more
or
fewer
samples
sent
to
the
analyzer
for
any
specific
group
of
packets
(especially
under
low
traffic
conditions).
The
actual
sample
rate
becomes
most
accurate
over
time,
and
under
higher
traffic
flow.
sFlow
sampling
has
the
following
restrictions:
Sample
Rate—The
fastest
sFlow
sample
rate
is
1
out
of
every
256
packets.
ACLs—sFlow
sampling
is
performed
before
ACLs
are
processed.
For
ports
configured
both
with
sFlow
sampling
and
one
or
more
ACLs,
sampling
will
occur
regardless
of
the
action
of
the
ACL.
Port
Mirroring—sFlow
sampling
will
not
occur
on
mirrored
traffic.
If
sFlow
sampling
is
enabled
on
a
port
that
is
configured
as
a
port
monitor,
the
mirrored
traffic
will
not
be
sampled.
Note:
Although
sFlow
sampling
is
not
generally
a
CPU
‐
intensive
operation,
configuring
fast
sampling
rates
(such
as
once
every
256
packets)
on
ports
under
heavy
traffic
loads
can
cause
switch
CPU
utilization
to
reach
maximum.
Use
larger
rate
values
for
ports
that
experience
heavy
traffic.
Содержание ThinkSystem NE2552E
Страница 27: ... Copyright Lenovo 2018 27 Part 1 Getting Started ...
Страница 28: ...28 NE2552E Application Guide for ENOS 8 4 ...
Страница 70: ...70 NE2552E Application Guide for ENOS 8 4 ...
Страница 85: ... Copyright Lenovo 2018 85 Part 2 Securing the Switch ...
Страница 86: ...86 NE2552E Application Guide for ENOS 8 4 ...
Страница 112: ...112 NE2552E Application Guide for ENOS 8 4 ...
Страница 134: ...134 NE2552E Application Guide for ENOS 8 4 ...
Страница 154: ...154 NE2552E Application Guide for ENOS 8 4 ...
Страница 194: ...194 NE2552E Application Guide for ENOS 8 4 ...
Страница 218: ...218 NE2552E Application Guide for ENOS 8 4 ...
Страница 234: ...234 NE2552E Application Guide for ENOS 8 4 ...
Страница 238: ...238 NE2552E Application Guide for ENOS 8 4 ...
Страница 239: ... Copyright Lenovo 2018 239 Part 4 Advanced Switching Features ...
Страница 240: ...240 NE2552E Application Guide for ENOS 8 4 ...
Страница 242: ...242 NE2552E Application Guide for ENOS 8 4 ...
Страница 278: ...278 NE2552E Application Guide for ENOS 8 4 ...
Страница 284: ...284 NE2552E Application Guide for ENOS 8 4 ...
Страница 314: ...314 NE2552E Application Guide for ENOS 8 4 ...
Страница 338: ...338 NE2552E Application Guide for ENOS 8 4 ...
Страница 374: ...374 NE2552E Application Guide for ENOS 8 4 ...
Страница 388: ...388 NE2552E Application Guide for ENOS 8 4 ...
Страница 418: ...418 NE2552E Application Guide for ENOS 8 4 ...
Страница 430: ...430 NE2552E Application Guide for ENOS 8 4 ...
Страница 432: ...432 NE2552E Application Guide for ENOS 8 4 ...
Страница 436: ...436 NE2552E Application Guide for ENOS 8 4 ...
Страница 460: ...460 NE2552E Application Guide for ENOS 8 4 ...
Страница 461: ... Copyright Lenovo 2018 461 Part 7 Network Management ...
Страница 462: ...462 NE2552E Application Guide for ENOS 8 4 ...
Страница 476: ...476 NE2552E Application Guide for ENOS 8 4 ...
Страница 498: ...498 NE2552E Application Guide for ENOS 8 4 ...
Страница 520: ...520 NE2552E Application Guide for ENOS 8 4 ...
Страница 534: ...534 NE2552E Application Guide for ENOS 8 4 ...
Страница 536: ...536 NE2552E Application Guide for ENOS 8 4 ...
Страница 544: ...544 NE2552E Application Guide for ENOS 8 4 ...
Страница 549: ... Copyright Lenovo 2018 549 Part 9 Appendices ...
Страница 550: ...550 NE2552E Application Guide for ENOS 8 4 ...
Страница 566: ...566 NE2552E Application Guide for ENOS 8 4 ...
Страница 572: ...572 NE2552E Application Guide for ENOS 8 4 ...
Страница 573: ......
Страница 574: ...Part Number 01KN246 Printed in USA IP P N 01KN246 ...