NE2552E Application Guide for ENOS 8.4
How Flooding Impacts MLD
When
flood
option
is
disabled,
the
unknown
multicast
traffic
is
discarded
if
no
Mrouters
are
learned
on
the
switch.
You
can
set
the
flooding
behavior
by
configuring
the
flood
and
cpu
options.
You
can
optimize
the
flooding
to
ensure
that
unknown
IP
multicast
(IPMC)
data
packets
are
not
dropped
during
the
learning
phase.
The
flooding
options
include:
flood
:
Enable
hardware
flooding
in
VLAN
for
the
unregistered
IPMC;
This
option
is
enabled
by
default.
cpu
:
Enable
sending
unregistered
IPMC
to
the
Mrouter
ports.
However,
during
the
learning
period,
there
will
be
some
packet
loss.
The
cpu
option
is
enabled
by
default.
You
must
ensure
that
the
flood
and
optflood
options
are
disabled.
optflood
:
Enable
optimized
flooding
to
allow
sending
the
unregistered
IPMC
to
the
Mrouter
ports
without
having
any
packet
loss
during
the
learning
period;
This
option
is
disabled
by
default;
When
optflood
is
enabled,
the
flood
and
cpu
settings
are
ignored.
The
flooding
parameters
must
be
configured
per
VLAN.
Enter
the
following
command
to
set
the
flood
or
cpu
options:
MLD Querier
An
Mrouter
acts
as
a
Querier
and
periodically
(at
short
query
intervals)
sends
query
messages
in
the
subnet.
If
there
are
multiple
Mrouters
in
the
subnet,
only
one
can
be
the
Querier.
All
Mrouters
on
the
subnet
listen
to
the
messages
sent
by
the
multicast
address
listeners,
and
maintain
the
same
multicast
listening
information
state.
All
MLDv2
queries
are
sent
with
the
FE80::/64
link
‐
local
source
address
prefix.
Querier Election
Only
one
Mrouter
can
be
the
Querier
per
subnet.
All
other
Mrouters
will
be
non
‐
Queriers.
MLD
versions
1
and
2
elect
the
Mrouter
with
the
numerically
lowest
IPv6
address
as
the
Querier.
If
the
switch
is
configured
as
an
Mrouter
on
a
subnet,
it
also
acts
as
a
Querier
by
default
and
sends
multiple
general
queries.
If
the
switch
receives
a
general
query
from
another
Querier
with
a
numerically
lower
IPv6
address,
it
sets
the
other
querier
present
timer
to
the
other
querier
present
timeout
,
and
changes
its
state
to
non
‐
Querier.
When
the
other
querier
present
timer
expires,
it
regains
the
Querier
state
and
starts
sending
general
queries.
Note:
When
MLD
Querier
is
enabled
on
a
VLAN,
the
switch
performs
the
role
of
an
MLD
Querier
only
if
it
meets
the
MLD
Querier
election
criteria.
NE2552E(config)#
vlan
<VLAN
ID>
NE2552E(config-vlan)#
[no] flood
NE2552E(config-vlan)#
[no] cpu
NE2552E(config-vlan)#
[no] optflood
Содержание ThinkSystem NE2552E
Страница 27: ... Copyright Lenovo 2018 27 Part 1 Getting Started ...
Страница 28: ...28 NE2552E Application Guide for ENOS 8 4 ...
Страница 70: ...70 NE2552E Application Guide for ENOS 8 4 ...
Страница 85: ... Copyright Lenovo 2018 85 Part 2 Securing the Switch ...
Страница 86: ...86 NE2552E Application Guide for ENOS 8 4 ...
Страница 112: ...112 NE2552E Application Guide for ENOS 8 4 ...
Страница 134: ...134 NE2552E Application Guide for ENOS 8 4 ...
Страница 154: ...154 NE2552E Application Guide for ENOS 8 4 ...
Страница 194: ...194 NE2552E Application Guide for ENOS 8 4 ...
Страница 218: ...218 NE2552E Application Guide for ENOS 8 4 ...
Страница 234: ...234 NE2552E Application Guide for ENOS 8 4 ...
Страница 238: ...238 NE2552E Application Guide for ENOS 8 4 ...
Страница 239: ... Copyright Lenovo 2018 239 Part 4 Advanced Switching Features ...
Страница 240: ...240 NE2552E Application Guide for ENOS 8 4 ...
Страница 242: ...242 NE2552E Application Guide for ENOS 8 4 ...
Страница 278: ...278 NE2552E Application Guide for ENOS 8 4 ...
Страница 284: ...284 NE2552E Application Guide for ENOS 8 4 ...
Страница 314: ...314 NE2552E Application Guide for ENOS 8 4 ...
Страница 338: ...338 NE2552E Application Guide for ENOS 8 4 ...
Страница 374: ...374 NE2552E Application Guide for ENOS 8 4 ...
Страница 388: ...388 NE2552E Application Guide for ENOS 8 4 ...
Страница 418: ...418 NE2552E Application Guide for ENOS 8 4 ...
Страница 430: ...430 NE2552E Application Guide for ENOS 8 4 ...
Страница 432: ...432 NE2552E Application Guide for ENOS 8 4 ...
Страница 436: ...436 NE2552E Application Guide for ENOS 8 4 ...
Страница 460: ...460 NE2552E Application Guide for ENOS 8 4 ...
Страница 461: ... Copyright Lenovo 2018 461 Part 7 Network Management ...
Страница 462: ...462 NE2552E Application Guide for ENOS 8 4 ...
Страница 476: ...476 NE2552E Application Guide for ENOS 8 4 ...
Страница 498: ...498 NE2552E Application Guide for ENOS 8 4 ...
Страница 520: ...520 NE2552E Application Guide for ENOS 8 4 ...
Страница 534: ...534 NE2552E Application Guide for ENOS 8 4 ...
Страница 536: ...536 NE2552E Application Guide for ENOS 8 4 ...
Страница 544: ...544 NE2552E Application Guide for ENOS 8 4 ...
Страница 549: ... Copyright Lenovo 2018 549 Part 9 Appendices ...
Страница 550: ...550 NE2552E Application Guide for ENOS 8 4 ...
Страница 566: ...566 NE2552E Application Guide for ENOS 8 4 ...
Страница 572: ...572 NE2552E Application Guide for ENOS 8 4 ...
Страница 573: ......
Страница 574: ...Part Number 01KN246 Printed in USA IP P N 01KN246 ...