Diagnostic Error Code
FRU/Action
018-250-XXX
PCI Card Services error
1. PCI card
2. Riser card, if installed.
3. System board
020-000-XXX
PCI Interface Test Passed
No action
020-0XX-XXX
PCI Interface error
1. PCI card
2. Riser card, if installed.
3. System board
020-195-XXX
PCI Test aborted by user
Information only Restart the test, if necessary
020-196-XXX
PCI test halt, error threshold exceeded
1. Press F3 to review the log file.
2. Restart the test to reset the log file.
020-197-XXX
PCI test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 37.
2. Re-run test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
020-198-XXX
PCI test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 37.
2. Flash the system and re-test. See “Updating
(flashing) the BIOS” on page 229.
3. Go to “Undetermined problems” on page 67.
020-199-XXX
PCI test failed, cause unknown
1. Go to “Undetermined problems” on page 67.
2. Flash the system and re-test. See “Updating
(flashing) the BIOS” on page 229.
3. Replace component under function test.
020-262-XXX
PCI system error
1. PCI card
2. Riser card, if installed.
3. System board
025-000-XXX
IDE interface Test Passed
No action
025-00X-XXX 025-01X-XXX
IDE interface failure
1. IDE signal cable
2. Check power supply voltages.
3. Reseat IDE signal cable.
4. IDE device
5. System board
025-027-XXX
IDE interface Configuration/Setup error
1. IDE signal cable
2. Flash the system. See “Updating (flashing) the
BIOS” on page 229.
3. Reseat IDE signal cable.
4. IDE device
5. System board
Chapter 8
.
Symptom-to-FRU Index
55
Содержание ThinkStation C20
Страница 1: ...ThinkStation Hardware Maintenance Manual Machine Types 4262 4263 4264 4265 4266 4269 4271 and 4272 ...
Страница 2: ......
Страница 3: ...ThinkStation Hardware Maintenance Manual Machine Types 4262 4263 4264 4265 4266 4269 4271 and 4272 ...
Страница 15: ...Chapter 2 Safety information 9 ...
Страница 16: ... 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs 1 2 PERIGO 10 ThinkStation Hardware Maintenance Manual ...
Страница 19: ...Chapter 2 Safety information 13 ...
Страница 20: ...1 2 14 ThinkStation Hardware Maintenance Manual ...
Страница 21: ...Chapter 2 Safety information 15 ...
Страница 27: ...Chapter 2 Safety information 21 ...
Страница 31: ...Chapter 2 Safety information 25 ...
Страница 74: ...68 ThinkStation Hardware Maintenance Manual ...
Страница 118: ...112 ThinkStation Hardware Maintenance Manual ...
Страница 240: ...234 ThinkStation Hardware Maintenance Manual ...
Страница 245: ......
Страница 246: ...Part Number 89Y7336 Printed in USA 1P P N 89Y7336 89Y7336 ...