6. Follow this sequence to remove the four screws that secure the heat sink and fan assembly to the
system board:
a. Partially remove screw
1
, then fully remove screw
2
, and then fully remove screw
1
.
b. Partially remove screw
3
, then fully remove screw
4
, and then fully remove screw
3
.
Note:
Carefully remove the four screws from the system board to avoid any possible damage to the
system board. The four screws cannot be removed from the heat sink and fan assembly.
Figure 28. Removing the heat sink and fan assembly
7. Lift the failing heat sink and fan assembly off the system board.
Notes:
a. You might have to gently twist the heat sink and fan assembly to free it from the microprocessor.
b. While handling the heat sink and fan assembly, do not touch the thermal grease on the bottom of it.
8. Place the new heat sink and fan assembly on the system board so that the four screws on the heat sink
and fan assembly are aligned with the corresponding holes on the system board. Make sure that you
properly place the heat sink and fan assembly so that you can easily connect the heat sink and fan
assembly cable to the microprocessor fan connector on the system board.
9. Follow this sequence to install the four screws to secure the new heat sink and fan assembly. See Figure
28 “Removing the heat sink and fan assembly” on page 51.
a. Partially tighten screw
1
, then fully tighten screw
2
, and then fully tighten screw
1
.
b. Partially tighten screw
3
, then fully tighten screw
4
, and then fully tighten screw
3
.
Note:
Do not over-tighten the screws.
10. Connect the heat sink and fan assembly cable to the microprocessor fan connector on the system
board. See “Locating parts on the system board” on page 24.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
Chapter 5
.
Replacing FRUs
51
Содержание ThinkSERVER TS130
Страница 1: ...ThinkServer TS130 Hardware Maintenance Manual Machine Types 1098 1100 1105 and 1106 ...
Страница 16: ...12 ThinkServer TS130 Hardware Maintenance Manual ...
Страница 24: ...20 ThinkServer TS130 Hardware Maintenance Manual ...
Страница 30: ...26 ThinkServer TS130 Hardware Maintenance Manual ...
Страница 84: ...80 ThinkServer TS130 Hardware Maintenance Manual ...
Страница 108: ...104 ThinkServer TS130 Hardware Maintenance Manual ...
Страница 126: ...122 ThinkServer TS130 Hardware Maintenance Manual ...
Страница 127: ......
Страница 128: ...Part Number Printed in China 1P P N ...