8. Position the new memory module over the memory slot. Make sure that the notch
1
on the new memory
module is aligned with the key
2
in the memory slot. Then, press the new memory module straight down
into the memory slot until the retaining clips close and the new memory module snaps into position.
Note:
If there is a gap between the memory module and the retaining clips, the memory module has
not been correctly installed. Open the retaining clips, remove the memory module, and then reinstall it
into the slot.
Figure 13. Installing a memory module
9. Reinstall the PCI Express x16 graphics card if you have removed it.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
• To complete the installation or replacement, go to “Completing the parts replacement” on page 64.
Installing or replacing the optical drive
Attention:
Do not open your server or attempt any repair before reading and understanding the
Safety Information
and the
Warranty and Support Information
on the documentation DVD that came with your product, and “Guidelines” on page
27. To obtain a copy of the publications, go to:
http://support.lenovo.com
This section provides instructions on how to install or replace the optical drive.
To install or replace an optical drive, do the following:
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
2. Remove the server cover. See “Removing the server cover” on page 31.
3. Remove the front bezel. See “Removing and reinstalling the front bezel” on page 32.
4. Depending on whether you are installing or replacing an optical drive, do one of the following:
• If you are installing a secondary optical drive, remove the plastic panel in the front bezel for the
drive bay you want to use. If there is a metal static shield installed in the drive bay, remove the
metal static shield.
Chapter 5
.
Replacing FRUs
39
Содержание ThinkSERVER TS130
Страница 1: ...ThinkServer TS130 Hardware Maintenance Manual Machine Types 1098 1100 1105 and 1106 ...
Страница 16: ...12 ThinkServer TS130 Hardware Maintenance Manual ...
Страница 24: ...20 ThinkServer TS130 Hardware Maintenance Manual ...
Страница 30: ...26 ThinkServer TS130 Hardware Maintenance Manual ...
Страница 84: ...80 ThinkServer TS130 Hardware Maintenance Manual ...
Страница 108: ...104 ThinkServer TS130 Hardware Maintenance Manual ...
Страница 126: ...122 ThinkServer TS130 Hardware Maintenance Manual ...
Страница 127: ......
Страница 128: ...Part Number Printed in China 1P P N ...