2. Remove the server cover. See “Removing the server cover” on page 31.
3. Locate the rear fan assembly. See “Internal components” on page 25.
4. Disconnect the rear fan assembly cable from the system fan connector on the system board. See
“Locating parts on the system board” on page 24.
5. The rear fan assembly is attached to the chassis by four rubber mounts. Remove the rear fan assembly
by cutting the rubber mounts and gently pulling the rear fan assembly out of the chassis.
Figure 32. Removing the rear fan assembly
6. Install the new rear fan assembly by aligning the new rubber mounts with the corresponding holes in the
chassis and push the rubber mounts through the holes.
Note:
The new rear fan assembly will have four new rubber mounts attached.