3. Remove or disconnect the following devices, one at a time, until you find the
failure. Turn on the server and reconfigure it each time.
v
Any external devices.
v
Surge-suppressor device (on the server).
v
Modem, printer, mouse, and non-Lenovo devices.
v
Each adapter.
v
Hard disk drives.
v
Memory modules. The minimum configuration requirement is 1 GB (two 512
MB DIMM, in DIMM slots 1 and 4).
v
Service processor (Remote Supervisor Adapter II SlimLine).
The following minimum configuration is required for the server to start:
v
One microprocessor
v
Two 512 MB DIMMs
v
One power supply
v
Power backplane
v
Power cord
v
ServeRAID SAS controller
4. Turn on the server. If the problem remains, suspect the following components in
the following order:
a. Power backplane
b. System board
If the problem is solved when you remove an adapter from the server but the
problem recurs when you reinstall the same adapter, suspect the adapter; if the
problem recurs when you replace the adapter with a different one, suspect the riser
card.
If you suspect a networking problem and the server passes all the system tests,
suspect a network cabling problem that is external to the server.
Problem determination tips
Due to the variety of hardware and software combinations that can be encountered,
use the following information to assist you in problem determination. If possible,
have this information available when requesting assistance from Service Support
and Engineering functions.
v
Machine type and model
v
Microprocessor or hard disk upgrades
v
Failure symptom
– Do diagnostics fail?
– What, when, where, single, or multiple systems?
– Is the failure repeatable?
– Has this configuration ever worked?
– If it has been working, what changes were made prior to it failing?
– Is this the original reported failure?
v
Diagnostics version
– Type and version level
v
Hardware configuration
– Print (print screen) configuration currently in use
– BIOS level
v
Operating system software
– Type and version level
Chapter 5. Diagnostics
195
Содержание ThinkServer RD120
Страница 1: ...ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 2: ......
Страница 3: ...ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 8: ...vi ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 42: ...24 ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 218: ...200 ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 231: ......
Страница 232: ...Part Number 46U0863 Printed in USA 1P P N 46U0863 ...