1
Ribbon cable
3
Operator information panel
2
Release tabs
1
Operator information panel
2
Release latch
1. From the front of the server, thread the operator-information-panel ribbon cable
through the panel housing in the server; then, connect the ribbon cable to the
operator-panel connector (J50) on the system board (see “System-board
internal cable connectors” on page 11 for the location of the connector).
2. Slide the panel into the server until it clicks into place.
3. Inside the server, secure the ribbon cable to the top of the panel enclosure,
using the hook-and-loop fastener.
4. Install the cover (see “Installing the cover” on page 57).
5. Slide the server into the rack.
6. Reconnect the external cables; then, reconnect the power cords and turn on the
peripheral devices and the server.