v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447,” on page 25
to determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
217-198-xxx
Could not establish drive parameters.
1. Reseat the hard disk drive signal cable.
2. Reseat the hard disk drive.
3. Replace the following components in the order
shown, restarting the server each time:
a. Hard disk drive
b. Hard disk drive signal cable
c. Hard disk drive backplane
217-xxx-00n
Failed fixed disk test.
Note:
n is the number of the failed drive.
The hard disk drive numbers are on the
server front.
1. Reseat the hard disk drive indicated by n.
2. Replace the hard disk drive indicated by n.
301-xxx-000
Failed keyboard test.
Note:
After installing a USB keyboard, you
might have to use the Configuration/Setup
Utility program to enable keyboardless
operation and prevent the POST error
message 301 from being displayed during
startup.
1. Reseat the keyboard cable.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Keyboard
b. (Trained service technician only) System
board
405-xxx-000
Failed Ethernet test on Ethernet controller.
1. Run the Configuration/Setup Utility program and
make sure that Ethernet is not disabled and that
the BIOS code is at the latest level.
2. (Trained service technician only) Replace the
system board.
405-xxx-00n
Failed Ethernet test on adapter in PCI slot
n.
1. Reseat the Ethernet adapter in slot n.
2. Replace the Ethernet adapter in slot n.
3. (Trained service technician only) Replace the
system board.
415-xx-000
Failed modem test.
1. Reseat the modem cable.
Note:
Make sure that the modem is present and
attached to the server.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Modem
b. (Trained service technician only) System
board
Recovering the BIOS code
If the BIOS code has become damaged, such as from a power failure during an
update, you can recover the BIOS code using the boot block jumper and a BIOS
recovery diskette.
Chapter 5. Diagnostics
181
Содержание ThinkServer RD120
Страница 1: ...ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 2: ......
Страница 3: ...ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 8: ...vi ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 42: ...24 ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 218: ...200 ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 231: ......
Страница 232: ...Part Number 46U0863 Printed in USA 1P P N 46U0863 ...