and creating a RAID level-1 logical drive. If you select custom configuration, you
can select the two physical drives that you want to group into an array and create a
hot-spare drive.
Using express configuration:
To use express configuration, complete the following
steps:
1. In the ServeRAID Manager tree, click the controller.
2. Click
Express configuration
.
3. Click Next.
4. In the “Configuration summary” window, review the information. To change the
configuration, click
Modify arrays
.
5. Click
Apply
; when you are asked whether you want to apply the new
configuration, click
Yes
. The configuration is saved in the controller and in the
physical drives.
6. Exit from ServeRAID Manager and remove the CD from the CD-RW/DVD drive.
7. Restart the server.
Using custom configuration:
To use custom configuration, complete the following
steps:
1. In the ServeRAID Manager tree, click the controller.
2. Click
Custom configuration
.
3. Click
Next
.
4. In the “Create arrays” window, from the list of ready drives, select the drives
that you want to group into the array.
5. Click the (Add selected drives) icon to add the drives to the array.
6. If you want to configure a hot-spare drive, complete the following steps:
a. Click the
Spares
tab.
b. Select the physical drive that you want to designate as the hot-spare drive,
and click the (Add selected drives) icon.
7. Click
Next
.
8. Review the information in the “Configuration summary” window. To change the
configuration, click
Back
.
9. Click
Apply
; when you are asked whether you want to apply the new
configuration, click
Yes
. The configuration is saved in the controller and in the
physical drives.
10. Exit from ServeRAID Manager and remove the CD from the CD-RW/DVD
drive.
11. Restart the server.
Viewing the configuration:
You can use ServeRAID Manager to view information
about RAID controllers and the RAID subsystem (such as arrays, logical drives,
hot-spare drives, and physical drives). When you click an object in the ServeRAID
Manager tree, information about that object appears in the right pane. To display a
list of available actions for an object, click the object and click
Actions
.
Chapter 2. Configuration information and instructions
23
Содержание ThinkServer RD120
Страница 1: ...ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 2: ......
Страница 3: ...ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 8: ...vi ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 42: ...24 ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 218: ...200 ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 231: ......
Страница 232: ...Part Number 46U0863 Printed in USA 1P P N 46U0863 ...