v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447,” on page 25
to determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
System event/error log message
Action
+5v critical under voltage fault
1. Remove the following devices, which are powered by 5 volts:
v
All PCI adapters
v
USB devices
v
CD-RW/DVD drive
v
Tape drive, if one is installed
v
Hard disk drive backplane
2. Reinstall each I/O device removed in step 1 on page 186, one
at a time, restarting the server each time, to isolate a defective
device. Replace any defective device.
3. If the error continues, replace the power backplane. Restart the
server.
4. If the error continues, (trained service technician only) replace
the system board.
5V fault
1. Remove the following devices, which are powered by 5 volts:
v
All PCI adapters
v
USB devices
v
CD-RW/DVD drive
v
Tape drive, if one is installed
v
Hard disk drive backplane
2. Reinstall each I/O device removed in step 1 on page 186, one
at a time, restarting the server each time, to isolate a defective
device. Replace any defective device.
3. If the error continues, replace the power backplane. Restart the
server.
4. If the error continues, (trained service technician only) replace
the system board.
+2.5v critical over voltage fault
Information only
+2.5v critical under voltage fault
Information only
+1.8v critical over voltage fault
Information only
+1.8v critical under voltage fault
Information only
The system real time clock battery is no longer
reliable.
Replace the battery.
+3.3v critical over voltage fault
1. Remove all PCI adapters.
2. Reinstall each PCI adapter, one at a time, restarting the server
each time, to isolate a defective adapter. Replace any defective
adapter.
3. If the error continues, (trained service technician only) replace
the system board.
Chapter 5. Diagnostics
187
Содержание ThinkServer RD120
Страница 1: ...ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 2: ......
Страница 3: ...ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 8: ...vi ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 42: ...24 ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 218: ...200 ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 231: ......
Страница 232: ...Part Number 46U0863 Printed in USA 1P P N 46U0863 ...