To remove any of the 10 replaceable fans, complete the following steps.
1. Read the safety information that begins on page vii and “Installation guidelines”
on page 53.
2. Slide the server out of the rack and remove the cover (see “Removing the
cover” on page 56). The LED on the failing fan will be lit.
Attention:
To ensure proper system cooling, do not remove the top cover for
more than 30 minutes during this procedure.
3. Remove the failed fan
1
from the server:
a. Place your fingers into the two handles on the top of the failing fan.
b. Pull the handles toward each other and lift the fan out of the server.
4. If you are instructed to return the fan, follow all packaging instructions, and use
any packaging materials for shipping that are supplied to you.
Installing a hot-swap fan
For proper cooling, the server requires that five fans be installed for each power
supply that is installed.
The server comes with five replaceable fans. If you install a second power supply,
you must install the complete set of five fans that come with the power-supply.
Important:
Only the configurations that are shown in the following table are
supported. The fan numbers are printed on the microprocessor air baffle.
Installed power supplies
Required fans
Power supply 1
Fans in locations 3, 4, 8, 9, and 10
Power supplies 1 and 2
All 10 fans
Attention:
To ensure proper server operation, if a fan fails, replace it as soon as
possible.
92
ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual
Содержание ThinkServer RD120
Страница 1: ...ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 2: ......
Страница 3: ...ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 8: ...vi ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 42: ...24 ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 218: ...200 ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 231: ......
Страница 232: ...Part Number 46U0863 Printed in USA 1P P N 46U0863 ...