1
Drive cage
2
SCSI terminator
5. Make sure that the tape-drive power cable is connected to the tape-drive power
connector, J100 (see “System-board internal cable connectors” on page 11 for
the location of the power connector).
6. Install the fan-bracket assembly.
7. Install the cover (see “Installing the cover” on page 57).
8. Slide the server into the rack.
9. Reconnect the external cables; then, reconnect the power cords and turn on the
peripheral devices and the server.
Attention:
In a dc power environment, only trained service personnel other
than Lenovo service technicians are authorized to connect or disconnect power
to the dc power supply. See the documentation that comes with each dc power
supply.
Removing a memory module (DIMM)
To remove a DIMM, complete the following steps.
1. Read the safety information that begins on page vii and “Installation guidelines”
on page 53.
2. Turn off the server and peripheral devices and disconnect all power cords and
external cables.
Chapter 4. Removing and replacing server components
87
Содержание ThinkServer RD120
Страница 1: ...ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 2: ......
Страница 3: ...ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 8: ...vi ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 42: ...24 ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 218: ...200 ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Страница 231: ......
Страница 232: ...Part Number 46U0863 Printed in USA 1P P N 46U0863 ...