Event Specific Data - Optional data is provided with this event.
MEL_DATA_DIAG_TEST_ID
RecoveryFailureType - N/A
MEL_EV_DIAG_READ_FAILURE_ALT - 0x560E
This event occurs when: Runtime Diagnostics Read test failed on the alternate controller.
Event Name - Runtime Diagnostics error Diagnostic read failure on alternate controller
Event description: This controller's alternate failed diagnostics read test
Event Group - Runtime Diagnostics
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_DIAG_WRITE_FAILURE - 0x560F
This event occurs when: Runtime Diagnostics Write test failed on this controller.
Event Name - Runtime Diagnostics error Diagnostic write test failed
Event description: Diagnostics write test failed on controller
Event Group - Runtime Diagnostics
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is provided with this event.
MEL_DATA_DIAG_TEST_ID
RecoveryFailureType - N/A
MEL_EV_DIAG_WRITE_FAILURE_ALT - 0x5610
This event occurs when: Runtime Diagnostics Write test failed on the alternate controller.
Event Name - Runtime Diagnostics error Diagnostic write test failed on alternate controller
Event description: This controller's alternate failed diagnostics write test
256
ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures
Содержание DE120S
Страница 96: ...90 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Страница 282: ...276 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Страница 284: ...278 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Страница 291: ......
Страница 292: ......