RecoveryFailureType - N/A
MEL_EV_LINE_MISSING - 0x280A
This event occurs when: An expected subsystem line is removed.
Event Name - Line Missing
Event description: Controller tray component removed
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Enclosure (0x0, 0xA)
Event Specific Data - Optional data is provided with this event.
MEL_SYMBOL_DATA_SLOTNUMBER
RecoveryFailureType - REC_REMOVED_SUPPORT_CRU ( removedSupportCRU.html )
MEL_EV_LINE_FAILED - 0x280B
This event occurs when: A subsystem line has transitioned to the Failed state.
Event Name - Line Failed
Event description: Controller tray component failed
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Enclosure (0x0, 0xA)
Event Specific Data - Optional data is provided with this event.
MEL_SYMBOL_DATA_SLOTNUMBER
RecoveryFailureType - REC_FAILED_ICC_CRU ( failedInterconnectCRU.html ), REC_SUPPORT_CRU_
NOINPUT ( supportCRUNoInput.html )
MEL_EV_ENCL_FAIL - 0x280D
This event occurs when: An enclosure has transitioned to the Failed state.
Event Name - Enclosure Fail
Event description: Drive tray component failed or removed
228
ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures
Содержание DE120S
Страница 96: ...90 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Страница 282: ...276 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Страница 284: ...278 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Страница 291: ......
Страница 292: ......