background image

 

 

   

 

 

Operational Instruction 

(Original)

 

 

Distribution box 

Type 07-56..-…./…. 

 

 

BARTEC 
Varnost d.o.o. 

Cesta 9.avgusta 59 
1410 Zagorje ob Savi 
Slovenia 

Tel.:  +386 59 221 471 
Fax:  +386 59 221 470 

[email protected] 
www.bartecvarnost.si 

Reservation

 

Technical data subject to change without notice. Changes, errors and 
misprints may not be used as a basis for any claim for damages. 

EN 1/3

 

 

 

 

 

 

 

 

 

 

Explosion protection 

 

 

Technical data 

 

ATEX 

Ex type of protection 

Type 07-56.2-…./…. 

  II 2G Ex e IIC T6, T5 Gb 

  II 2D Ex tb IIIC T80 °C,T95 °C Db   

 

Type 07-56.3-…./…. 

  II 2G Ex e ia/ib IIC T6, T5 Gb 

  II 2D Ex tb IIIC T80 °C,T95 °C Db 

 

Type 07-56.4-…./…. 

  II 2G Ex ia/ib IIC T6 Gb 

  II 2D Ex tb IIIC T80 °C Db 

  II 2D Ex ia/ib IIIC T80 °C Db 

 

Certification 

IBExU 99 ATEX 1096 

IECEx 

Ex type of protection 

Type 07-56.2-…./…. 

 

Ex e IIC T6, T5 Gb 

 

Ex tb IIIC T80 °C, T95 °C Db  

 

Type 07-56.3-…./…. 

 

Ex e ia/ib IIC T6, T5 Gb 

 

Ex tb IIIC T80 °C, T95 °C Db 

 

Type 07-56.4-…./…. 

 

Ex ia/ib IIC T6 Gb Ta<55

°

 

Ex tb IIIC T80 °C Db Ta<55

°

 

Ex ia/ib IIIC T80 °C Db Ta<55

°

 

Certification 

IECEx IBE 09.0017 

Ambient temperature ranges 

Depending on the installed components; ob-
serve the specifications on the type label.  

 

EPDM-Seal:  -20 °C to +55 °C 

(T5)

 

 

(-4 °F to +131 °F) 

(T5)

 

-20 °C to +40 °C 

(T6)

 

(-4 °F to +104 °F) 

(T6)

 

Silicon-Seal:  -55 °C to +55 °C 

(T5)

 

 

(-67 °F to +131 °F) 

(T5)

 

-55 °C to +40 °C 

(T6)

 

(-67 °F to +104 °F) 

(T6)

 

Approved for zones 

1 and 2 
21 and 22 
 

Protection class 

Max. IP66  

Rated voltage (U

e

AC/DC 1000 V 

Mechanical strength 

Impact energy: 7 Joule 

Enclosure material 

– 

1.4301,  AISI  304  high  quality 
stainless steel 

– 

1.4404,  AISI  316  L  high  quality 
stainless steel 

Surface 

– 

brushed 

– 

painted 

– 

electro polished 

Lid screws 

Stainless steel, captive 

Terminals 

Certified connecting and/or rail-mounted 
terminals with a maximum rated voltage of 
1000 V AC/DC and a maximum rated cross 
section of 300 mm². 
 
Tightening torques, see manufacturer`s in-
structions. 

Dimensions  

From 
100 x 100 x 60 mm 
(3.9 x 3.9 x 2.4 in) 
to  
1000 x 1200 x 400 mm 
(47.2 x 47.2 x 15.7 in) 
see also Bartec catalogue 

 

V

S

 –

 1

01

 3

51

 (

is

su

N

I /

 2

.1

1.

20

16

Note on instructions 

When working in hazardous areas, the safety of 
personnel  and  equipment  depends  on  compli-
ance  with  the  relevant  safety  regulations.  The 
people  in  charge  of  installation  and  mainte-
nance bear a special responsibility. It is essen-
tial  that  they  have  an  exact  knowledge  of  the 
applicable rules and regulations. 
The instructions provide a summary of the most 
important  safety  measures  and  must  be  read 
by  everyone  working  with  the  product  so  that 
they will be familiar with the correct handling of 
the product. 
The  instructions  have  to  be  kept  for  future 
reference and must be available throughout the 
expected life of the product. 
 

Description  

The  BARTEC  Varnost  distribution  boxes,  type 
07-56..-..../...., are available as enclosures with 
lid  or  as  cabinets  with  door.  The  distribution 
boxes  are  used  for  connection  with  lights, 
devices and sensors. 
The  walls  of  the  enclosure,  lid/door  and  base 
consist  of  several  edged  and  welded  high-
grade stainless steel of at least 1 mm (0.04 in) 
thickness. The flange plates with tapped holes 
for the cable and conduit entries are at least 3 
mm (0.12 in) thick.  
The IP protection class is realized by a seal in 
the lid or in the door. 
The distribution boxes are mounted with mount-
ing  brackets  found  outside  of  the  enclosure 
wall.  
The  distribution  boxes  are  also  suitable  for 
intrinsically safe electric circuit  connection. For 
this application, special marking is required. 
The BARTEC Varnost distribution boxes can be 
used in hazardous areas of both zone 1 and 2  
with  certified  explosion  subgroups  II  and  the
temperature class T5/T6 and as well as in zone
21 and 22 with certified max. surface tempera-
ture. 

 

Отзывы: