Event Category - State (0x5)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_FAIL_VDSK_DELAYED - 0x2252
This event occurs when: A specified device is failed during interrupted write processing. SK/ASC/ASCQ =
0x06/0x3F/0x98 will be offloaded for each failing device.
Event Name - Fail Vdisk Delayed
Event description: Drive marked offline during interrupted write
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is provided with this event.
MEL_DATA_VOL_LABEL
RecoveryFailureType - N/A
MEL_EV_UNCERTIFIED_DRIVE - 0x2260
This event occurs when: An uncertified drive has been detected in the array.
Event Name - Uncertified Drive
Event description: Uncertified Drive Detected
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_UNCERTIFIED_DRIVE ( uncertifiedDrive.html )
.