Step 2. Restart the server.
Step 3. When the prompt
<F12> Select Boot Device
is displayed, press F12.
Step 4. Use the Up arrow and Down arrow keys to select an item from the menu and press Enter.
The next time the server starts, it returns to the startup sequence that is set in the Setup utility.
Starting the backup server firmware
This topic provides instructions on starting the backup copy of the server firmware in the event that the
primary copy of the firmware becomes damaged or corrupt.
The standard I/O book board contains a backup copy area for the server firmware. This is a secondary copy
of the server firmware that you update only during the process of updating the server firmware. If the primary
copy of the server firmware becomes damaged, use this backup copy.
To force the server to start from the backup copy, turn off the server; then, change the position of switch 7 on
the SW1 switch block to ON. See “Jumpers, switches, and buttons on standard I/O book board” on page 37
for more information about the jumpers, switches, and buttons on the server. The following illustration shows
the location of the SW1 switch block.
NMI
button
SW1
switch
block
SW2
switch
block
(reserved)
IMM security
jumper (J35)
8
7
6
5
4
3
2
1
OFF
ON
1
2
3
Use the backup copy of the server firmware until the primary copy is restored. After the primary copy is
restored, turn off the server; then, change the position of switch 7 back to OFF (the default).
The Update
Xpress
System Pack Installer
This topic provides information about the Update
Xpress
System Pack Installer program.
The Update
Xpress
System Pack Installer detects supported and installed device drivers and firmware in the
server and installs available updates. For additional information and to download the Update
Xpress
System
Pack Installer, go to the ToolsCenter for Lenovo x86 servers website at
https://datacentersupport.lenovo.com/
and click
UpdateXpress System Pack Installer
.
130
System x3850 X6 and x3950 X6 Installation and Service Guide
Содержание 6241
Страница 1: ...System x3850 X6 and x3950 X6 Installation and Service Guide Machine Type 6241 ...
Страница 6: ...iv System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 56: ...42 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 82: ...68 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 132: ...118 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 158: ...144 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 214: ...200 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 358: ...344 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1938: ...1924 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1964: ...1950 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1968: ...1954 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1975: ...Taiwan Class A compliance statement Appendix F Notices 1961 ...
Страница 1976: ...Taiwan BSMI RoHS declaration 1962 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1988: ...1974 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1989: ......
Страница 1990: ......