User Response
1. Check if there is any other Power Supply event.
2. confirm power policy and configuration setting in Web GUI.
3. check line feeds.
4. check documentation for correct configuration.
Related links
– Solving power problems
– Installing power supplies
•
806f060d-0400ffff : Array [ComputerSystemElementName] has failed.
Drive 0 is part of an RAID array that is in the failed condition. To identify drives in the failed array all
member drives will report this message.
May also be shown as 806f060d0400ffff or 0x806f060d0400ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix:
PLAT
ID:
0176
User Response
– Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive
(s).
– Replace the hard disk drives that are indicated by a lit status LED.
– Recreate the array.
– Restore data from backup.
Related links
– Removing 2.5-inch and 1.8-inch hot-swap drives
– Replacing 2.5-inch and 1.8-inch hot-swap drives
•
806f060d-0401ffff : Array [ComputerSystemElementName] has failed.
Drive 1 is part of an RAID array that is in the failed condition. To identify drives in the failed array all
member drives will report this message.
May also be shown as 806f060d0401ffff or 0x806f060d0401ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
1110
System x3850 X6 and x3950 X6 Installation and Service Guide
Содержание 6241
Страница 1: ...System x3850 X6 and x3950 X6 Installation and Service Guide Machine Type 6241 ...
Страница 6: ...iv System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 56: ...42 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 82: ...68 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 132: ...118 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 158: ...144 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 214: ...200 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 358: ...344 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1938: ...1924 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1964: ...1950 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1968: ...1954 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1975: ...Taiwan Class A compliance statement Appendix F Notices 1961 ...
Страница 1976: ...Taiwan BSMI RoHS declaration 1962 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1988: ...1974 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1989: ......
Страница 1990: ......