Page 5
BLOWER DATA
EL296UH045XV36B BLOWER PERFORMANCE (less filter)
BOTTOM RETURN AIR
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
HEATING
1
Heating Speed
DIP Switch
Settings
First Stage Heating Speed - cfm
Second Stage Heating Speed - cfm
+24%
915
1125
+18%
865
1085
+12%
805
1040
+6%
780
985
Factory Default
740
925
–6%
665
875
–12%
630
800
–18%
585
735
COOLING
1
Cooling Speed
DIP Switch
Settings
First Stage Cooling Speed - cfm
Second Stage Cooling Speed - cfm
Low
Medium-Low Medium-High
2
High
Low
Medium-Low Medium-High
2
High
+
595
760
865
980
905
1075
1210
1370
Factory Default
540
660
785
890
815
980
1120
1255
–
485
600
695
790
720
885
1020
1135
1
Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific DIP Switch Settings.
2
Factory default setting.
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT.
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is selectable at 28% and 38% of the selected second stage cooling speed - minimum 250 cfm.
Lennox iHarmony
®
Zoning System Applications - Minimum blower speed is 250 cfm.
EL296UH045XV36B BLOWER MOTOR WATTS (COOLING)
1
Cooling Speed
DIP Switch
Settings
Motor Watts @ Various External Static Pressures - in. wg.
First Stage
Second Stage
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
+ Setting
Cooling
Speed
Low
18
33
54
73
88 107 124 144 158 64
87
112
140 171
196 225
243 267 297 317
Med-low
36
58
82
100 120
141
166
182
211
127 138 185 214 237 271
296 326
348
369 390
Med-High 57
86
103
128
159
187
210 233 255
189
219 250
280
305
340 377 411 439 464 483
High
91
114 142 177 217
235 259
285
311
267 281
322 363
400 433 468
502 521 552
549
Factory Default
Cooling
Speed
Low
16
34
52
67
86
98
120
138
155
46
69
91 115
142 167 188
206 232 260
280
Med-low
25
35
65
85
110 125
140
155
180
93 110
138 173
209 230 255
280 304
325
343
Med-High 41
66
87
106 129
154 178
195 223 150 166 206
238 264
293 320
349 376
399
420
High
61
87
110
138
169
194
222
241
265 213
245
269 300
334 368
399
431 460 480
513
– Setting
Cooling
Speed
Low
10
28
40
56
76
89
106 122
137
33
52
78
97
116 132 159
174
202
224 238
Med-low 18
34
55
73
89 108 124 145
159 59
86 104
129 160
187
211
234
256
282
303
Med-High
29
45
72
92
114
129 151 166 193
107
122
157 188
221
247 273
302
324 343
361
High
44
67
89
111 135 160
183
200
227
160
185 214 246 277
302 335
364
391
414 435