Page 13
BLOWER DATA
EL296UH090XV36C BLOWER PERFORMANCE (less filter)
SINGLE SIDE RETURN AIR WITH OPTIONAL RETURN AIR BASE
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
HEATING
1
Heating Speed
DIP Switch
Settings
First Stage Heating Speed - cfm
Second Stage Heating Speed - cfm
+24%
1170
1250
+18%
1110
1200
+12%
1045
1145
+6%
995
1070
Factory Default
940
1010
–6%
880
950
–12%
815
895
–18%
775
825
COOLING
1
Cooling Speed
DIP Switch
Settings
First Stage Cooling Speed - cfm
Second Stage Cooling Speed - cfm
Low
Medium-Low Medium-High
2
High
Low
Medium-Low Medium-High
2
High
+
605
715
810
930
850
995
1165
1305
Factory Default
570
660
735
820
775
905
1050
1205
–
530
600
670
725
710
800
945
1070
1
Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific DIP Switch Settings.
2
Factory default setting.
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT.
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is selectable at 28% and 38% of the selected second stage cooling speed - minimum 250 cfm.
Lennox iHarmony
®
Zoning System Applications - Minimum blower speed is 250 cfm.
EL296UH090XV36C BLOWER MOTOR WATTS (COOLING)
1
Cooling Speed
DIP Switch
Settings
Motor Watts @ Various External Static Pressures - in. wg.
First Stage
Second Stage
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
+ Setting
Cooling
Speed
Low
12
29
43
59
75
92 111 123 139
41
62
86
102 123
145
165
185
205 229 253
Med-low 24
42
61
76
97
112 132 150 169
79 108
126
148 174
190
218 248 273 294
316
Med-High 38
56
81
99 115
138 157 176
199 131 152
184 208 237 264 289
320 339 361 390
High
61
85 104 127 144 171
192 212 239 205 226
258 283
312
344
365 393
410 437 466
Factory Default
Cooling
Speed
Low
9
26
37
54
67
83
97
112 130 30
50
72
87 108 127 149 167 184
209 226
Med-low
19
37
53
67
83
101 119 135 153 62
86
101 129
144
165
189
215 232 251
275
Med-High 27
48
65
82
101 119 139 161
177
91
114 140
163 195 220 239 265
289
315 339
High
42
62
85
99 121
143
162
183
203
149 167
201
228 258 289
316 333 355
389 403
– Setting
Cooling
Speed
Low
8
23
35
51
62
77
91
104
119 25
45
61
75
91 112 131
147
166
184 198
Med-low
13
29
46
60
78
93 110 125
140 40
61
81
103 119
143
162
179 204
220
245
Med-High
22
41
57
70
88
109
127 144
159
70
92 120 133 165
178
203 231
246 274
301
High
29
50
69
83
106 123
143 164 183
101
124
151
180
203
227 257 276
306 326
358