Page 15
BLOWER DATA
EL296UH090XV48C BLOWER PERFORMANCE (less filter)
SINGLE SIDE RETURN AIR
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
HEATING
1
Heating Speed
DIP Switch
Settings
First Stage Heating Speed - cfm
Second Stage Heating Speed - cfm
+24%
1400
1570
+18%
1380
1475
+12%
1310
1415
+6%
1255
1360
Factory Default
1210
1285
–6%
1125
1260
–12%
1080
1150
–18%
990
1115
COOLING
1
Cooling Speed
DIP Switch
Settings
First Stage Cooling Speed - cfm
Second Stage Cooling Speed - cfm
Low
Medium-Low Medium-High
2
High
Low
Medium-Low Medium-High
2
High
+
820
1005
1135
1290
1140
1340
1525
1725
Factory Default
755
880
1025
1150
1040
1235
1395
1565
–
680
815
925
1065
910
1120
1275
1400
1
Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific DIP Switch Settings.
2
Factory default setting.
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT.
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is selectable at 28% and 38% of the selected second stage cooling speed - minimum 380 cfm.
Lennox iHarmony
®
Zoning System Applications - Minimum blower speed is 380 cfm.
EL296UH090XV48C BLOWER MOTOR WATTS (COOLING)
1
Cooling Speed
DIP Switch
Settings
Motor Watts @ Various External Static Pressures - in. wg.
First Stage
Second Stage
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
+ Setting
Cooling
Speed
Low
43
65
85
96 119
134
156
179
199 102 131 155
189
216
249 282 304
331 359
387
Med-low
66
95 113
140 164 189
212
242 268 173
196
242 271
306
337
362
405 430 460 493
Med-High
95 126 151
180
210
242 277
302 320
243 277
316
371 412 457 492 534
566 605 651
High
143
166 203
243 282
309 333
368 389 368 410 453
511 562
604
651 690
730 771 809
Factory Default
Cooling
Speed
Low
36
48
73
86 108
120
140
152
168 75
101 125 156
178
215
244
259
288
320 339
Med-low
52
75
95 110 130 161
176
201 216 129
154
190
218 257
295 322
346 377 404 434
Med-High 70
94
125
146 172 198
230 252
275
190 222
270
299 325
368 398 439 470 508 549
High
100 131 162
197 228
260
298 328 347 275
310 359
400 445 469
525 562
597 642 682
– Setting
Cooling
Speed
Low
32
45
58
80
97
110 121 133
154
62
87
109 129 152
173
199 221 250 266 295
Med-low 45
63
82
99 119
137
150
171
193 95
124
150
180 207 240
269
297
325 356
375
Med-High
55
82
101 119
145 167
192 213 239
148 177
205
244 286
309
346 370 402 431 467
High
76
101
137
160
188 218 245 271
302
198
239
274 308 349 384 426 471
500
542 576