BLOWER DATA
EL296UH110XV48C BLOWER PERFORMANCE (less filter)
SINGLE SIDE RETURN AIR
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
HEATING
1
Heating Speed
DIP Switch
Settings
First Stage Heating Speed - cfm
Second Stage Heating Speed - cfm
+24%
1480
1580
+18%
1410
1505
+12%
1330
1415
+6%
1255
1365
Factory Default
1190
1270
–6%
1130
1205
–12%
1070
1120
–18%
1020
1060
COOLING
1
Cooling Speed
DIP Switch
Settings
First Stage Cooling Speed - cfm
Second Stage Cooling Speed - cfm
Low
Medium-Low Medium-High
2
High
Low
Medium-Low Medium-High
2
High
+
795
975
1065
1200
1085
1295
1515
1695
Factory Default
755
855
1000
1110
1015
1180
1375
1565
–
700
785
885
1025
920
1070
1235
1395
1
Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific DIP Switch Settings.
2
Factory default setting.
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT.
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is selectable at 28% and 38% of the selected second stage cooling speed - minimum 380 cfm.
Lennox iHarmony
®
Zoning System Applications - Minimum blower speed is 380 cfm.
EL296UH110XV48C BLOWER MOTOR WATTS (COOLING)
1
Cooling Speed
DIP Switch
Settings
Motor Watts @ Various External Static Pressures - in. wg.
First Stage
Second Stage
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
+ Setting
Cooling
Speed
Low
35
58
79
99 120
148
166 192 209
79 107 142 168
196 225
254 286 314 344 376
Med-low
52
81
103 132 153
178
212 236 262 130
167
199
237 272
313 350 392
419 457 486
Med-High
93
128
156
183 207 246 274 314
339 215
246
290
334 375 416 457 490 528
569
598
High
108 144 175 207 241 276 308 345 376 287
333
383 427 482
515
571 614
666
716 756
Factory Default
Cooling
Speed
Low
28
49
69
92 110
128 147 175
192 63
88
122
143
169
198 224
250
281
311 330
Med-low 40
65
85
110 135 155
180
205 235 100 136 166 195
227
261 291 329
358 394 423
Med-High
59
85
115 139 163 190 220
245 274 154
192 229
270
309
345 383 428 459
503
534
High
85
116
148 175
201 235 263 299 325
245 280 328 370 412 444 488
521
570 608
650
– Setting
Cooling
Speed
Low
25
42
60
82
103 113
137
152
173 46
72
94
120
146 170 197
226
249 268
293
Med-low
39
62
82
102 120
140
165
187 207 74
99
137
162 193
218 247 276
305
337
366
Med-High 43
71
92 116
142
165 190
217 243
113 150
181 214 247 286
320
358 388 425 451
High
65
89
125
146 173
201
227 254 285 164
202
244 285
315 356
398 441 476 518
550
Содержание EL296UH045XV36B
Страница 89: ...Page 89 VII Wiring and Sequence of Operation Ignition Control 103130 05 EL296 Schematic Diagram...
Страница 90: ...Page 90 Ignition Control 103130 05 and Blower Drive EL296 Units With Blower Drive...
Страница 91: ...Page 91 Ignition Control 107045 01...
Страница 92: ...Page 92 Ignition Control 107045 01 and Blower Drive...