Page 11
BLOWER DATA
EL296UH090XV36C BLOWER PERFORMANCE (less filter)
BOTTOM RETURN AIR
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
HEATING
1
Heating Speed
DIP Switch
Settings
First Stage Heating Speed - cfm
Second Stage Heating Speed - cfm
+24%
1215
1300
+18%
1140
1240
+12%
1100
1170
+6%
1020
1115
Factory Default
965
1070
–6%
915
970
–12%
850
925
–18%
805
855
COOLING
1
Cooling Speed
DIP Switch
Settings
First Stage Cooling Speed - cfm
Second Stage Cooling Speed - cfm
Low
Medium-Low Medium-High
2
High
Low
Medium-Low Medium-High
2
High
+
625
710
830
950
875
1040
1210
1360
Factory Default
565
670
760
860
800
945
1100
1245
–
520
610
685
785
720
840
970
1115
1
Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific DIP Switch Settings.
2
Factory default setting.
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT.
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is selectable at 28% and 38% of the selected second stage cooling speed - minimum 250 cfm.
Lennox iHarmony
®
Zoning System Applications - Minimum blower speed is 250 cfm.
EL296UH090XV36C BLOWER MOTOR WATTS (COOLING)
1
Cooling Speed
DIP Switch
Settings
Motor Watts @ Various External Static Pressures - in. wg.
First Stage
Second Stage
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
+ Setting
Cooling
Speed
Low
19
33
51
67
81
97
113
128 144 47
64
90 111
127
153
174
193 215
234
250
Med-low
35
52
76
90
108
130
146
166
185 87 114
130
158 184
205
227
252
278
301 321
Med-High
51
70
92
117 138
155
181
199 219
146 170
199 223
246 277
303 329
357 379
399
High
69
94
113 133 152
177 194
222
246
225 250
277 308
329 362 391
411 442 465 489
Factory Default
Cooling
Speed
Low
14
31
44
59
75
88 104
125
137 37
54
74
94 114
135 152
175 187
209 223
Med-low
29
46
63
80
95
114
133
146 164
65
87 108
130 152
173
196 222 236 262
283
Med-High
39
56
78
97 117 137
155
175
192 102
127
152
175
202
228 246 279
306
328 345
High
46
68
86
111 126
154 174 194 214 167 184 218
253
272
301 332 360
381 402 421
– Setting
Cooling
Speed
Low
11
27
39
57
70
84
99 113 131 26
45
61
81
96
118 134
152 169
189
205
Med-low
23
39
53
71
87
103
118
133
148 44
60
85 107 127
150 169
186 207
226
247
Med-High 24
43
56
79
97
111 129
149
165
75
101
117 140
160
182
215 235 255
275
296
High
33
51
69
94
111 131 150
170 186
112
134
160
186
220 236
264
293 311 335 363