Operation
Vento
®
1.0
19 / 52
Starting automatic dosing:
Warning!
Risk of injury!
Make sure that no other persons or animals are in the danger zone during operation.
Press the key.
Dosing starts when the speed is faster than 2 km/h and the hydraulics are
lowered.
c
F
V
Green LED lights up. Rotary feeder drive motor running.
The following is shown in the display:
•
Product name (spreading table used)
•
Speed of the rotary feeder
•
Travel speed
An audible signal indicates when dosing has started correctly. Three audible signals indicate there is a fault and
dosing has not been started.
The green LED flashes if the speed or lifting gear signal is not received.
Stopping automatic dosing:
The spreading procedure can be stopped at any time by pressing the key.
Otherwise, dosing is stopped automatically when the hydraulics are raised or the travel speed is less than 1.5 km/h.
The spreading procedure restarts when both signals are received again.
After an automatic interruption, it is necessary to press the key again in order to restart the dosing.
3.6 Setting the blower
Using the dial, it is possible to set the blower power according to the product type and output rate,
until achieving satisfactory material transport.
Advice!
Setting a high blower power increases energy consumption.
Lateral distribution can be varied by means of the blower power.