Operation
Vento
®
1.0
21 / 52
Press the key.
Green LED lights up.
Rotary feeder valve drive motor running.
The following appears on the display:
•
Manual: Manual operating mode
•
Speed of the rotary feeder in rpm
•
Dosing ON: Drive motor
Rotary feeder valve running.
M
l FV
O
Stopping dosing
Press the key.
Yellow LED lights up:
The drive motor stops.
M
l FV
O
FF
Manual operation with EHR
The EHR signal from the carrier vehicle or the signal from a lifting gear sensor (see
Chapter 3.4.5, "Electronic lifting
) stops the spreader automatically when the hydraulics are raised.
Dosing starts automatically when the hydraulics are lowered.
The spreading procedure can be stopped at any time by pressing the key.
3.9 Residual discharge
Caution!
Risk of environmental pollution due to incorrect handling of fertilisers!
Comply with regulations and laws of the country in question.
Make sure that no fertiliser is spilled onto the ground.
Comply with the instructions from the fertiliser manufacturer regarding handling, storage and
disposal of the fertilisers.
Advice!
To avoid damage to property after completing work, always perform a complete residual discharge of the
spreader.
Even if a visual inspection indicates that the spreader is empty, it can be expected that there will still be approx. 2
litres remaining in the spreader. The residual amount of granulate must be collected in containers with a sufficient
capacity. Empty out larger amounts through the residual discharge opening.
Residual discharge for smaller amounts:
Press the toggle switch twice within 1 second.
m
p yi g
Y
E