Operation
20 / 52
1.0
Vento
®
3.7 Changing the settings
The output rate, working width and product can be set directly. A product change is only possible if several products
have already been stored. "Product 1" is a factory setting. Creating new products, see
bles and calibration procedure"
Press toggle switch. The selected value flashes and can be set. To move to
the next item, or to return to operating mode, press the toggle switch again.
c
.
Press the
+/-
keys to switch between the stored products or to change the
numerical values.
3.8 Manual mode
In manual mode, the speed of the rotary feeder is set manually.
Setting
Press the Automatic dosing key.
This changes over between automatic dosing and manual mode.
Display in manual mode
The following appears on the display:
•
Manual: Manual operating mode
•
Speed of the rotary feeder in rpm
•
Dosing OFF: Rotary feeder valve drive motor off
Start dosing
Manual operation is possible with or without electronic lifting gear control (EHR).
Manual operation without EHR
Setting the speed
Press the
+/-
keys to change the speed.
Warning!
Risk of injury!
Make sure that no other persons or animals are in the danger zone during operation.