PRO1 Sentry Switched DC PDU
40 of 211
User Access Rights
The following table defines the user rights granted by the administrative user for access to PDU operations using
either the Web GUI or the Command Line interface (CLI). Only the options for which the user has access rights will
be available in the firmware for the user.
User Access Level
(highest to lowest)
Description
Administrator
Administrative user; full access for all configuration, user management, all outlet power
control actions (On, Off, Reboot), status, and serial/pass-thru ports.
Power User
Full access for all outlet power control actions (On, Off, Reboot), status, and serial/pass-
thru ports.
Note:
The Power User does not have access to user management.
User
Partial access for outlet power control actions (On, Off, Reboot), status, and pass-thru of
assigned outlets, outlet groups, and serial/pass-thru ports.
Reboot-Only User
Partial access for outlet power control actions (Reboot), status, and pass-thru of assigned
outlets, outlet groups, and serial/pass-thru ports.
On-Only User
Partial access for outlet power control actions (On), status, and pass-thru of assigned
outlets, outlet groups, and serial/pass-thru ports.
View-Only User
Partial access for status and pass-thru of assigned outlets, outlet groups, and serial/pass-
thru ports.
The administrative user can also grant administrative-level rights to other user accounts, allowing the PDU to have
more than one administrative user.
Administrative access rights cannot be removed from the default
admn
user account until an administrative user
grants administrative access rights to another user account.
To use administrative commands, the user must be granted administrative user access rights.
Содержание 48DCWC-04-2X100-D0NB
Страница 1: ......
Страница 2: ...Sentry Switched DC PDU 2 of 211...
Страница 10: ...Sentry Switched DC PDU 10 of 211 Mounting Bracket The 48DCWC 16 2X100 A0 mounting bracket...
Страница 12: ...Sentry Switched DC PDU 12 of 211 Mounting Bracket The 48DCWC 04 2X100 D0NB mounting bracket...
Страница 14: ...Sentry Switched DC PDU 14 of 211 Mounting Bracket The 48DCWC 12 2X100 A1NB mounting bracket...
Страница 16: ...Sentry Switched DC PDU 16 of 211 Mounting Bracket The 48DCWC 08 2X100 B0NB mounting bracket...
Страница 18: ...Sentry Switched DC PDU 18 of 211 Mounting Bracket The 48DCWC 04 4X070 D0NB mounting bracket...
Страница 20: ...Sentry Switched DC PDU 20 of 211 Mounting Bracket The 48DCWC 04 4X125 E0NB mounting bracket...
Страница 22: ...Sentry Switched DC PDU 22 of 211 Mounting Bracket The 48DCWC 10 2X300 E0NB mounting bracket...