Sierra M6
‐
2 SAS/SATA Protocol Analyzer User Manual
431
Sierra Trainer Generation Commands
LeCroy Corporation
COMINIT
Settings
COMINIT_NegLen
800
The number of bursts to send as part of this OOB
type.Each Burst is followed by an Idle. The Burst
‐
Idle
pairs are repeated the requested number of times,
and then followed by the Negation_length of Idle.
COMINIT_IdleLen
480
Burst time between each OOB idle in OOBIs.During
the specified period, the generator will send
ALIGN(0) at the specified speed.
COMINIT_BurstLen
160
Idle time between each OOB burst in OOBIs.During
the specified period, the generator will keep the line
at electric idle.
COMINIT_NumBursts
6
Negation time at the end of the OOB signal in
OOBIs.During the specified period, the generator will
keep the line at electric idle.
COMWAKE
Settings
COMWAKE_NegLen
280
The number of bursts to send as part of this OOB
type.Each Burst is followed by an Idle. The Burst
‐
Idle
pairs are repeated the requested number of times,
and then followed by the Negation_length of Idle.
COMWAKE_IdleLen
160
Burst time between each OOB idle in OOBIs.During
the specified period, the generator will send
ALIGN(0) at the specified speed.
COMWAKE_BurstLen
160
Idle time between each OOB burst in OOBIs.During
the specified period, the generator will keep the line
at electric idle.
COMWAKE_NumBursts
6
Negation time at the end of the OOB signal in
OOBIs.During the specified period, the generator will
keep the line at electric idle.
COMSAS Settings
COMSAS_NegLen
2400
The number of bursts to send as part of this OOB
type.Each Burst is followed by an Idle. The Burst
‐
Idle
pairs are repeated the requested number of times,
and then followed by the Negation_length of Idle.
COMSAS_IdleLen
1440
Burst time between each OOB idle in OOBIs.During
the specified period, the generator will send
ALIGN(0) at the specified speed.
COMSAS_BurstLen
160
Idle time between each OOB burst in OOBIs.During
the specified period, the generator will keep the line
at electric idle.
COMSAS_NumBursts
6
Negation time at the end of the OOB signal in
OOBIs.During the specified period, the generator will
keep the line at electric idle.
Setting
Default
Value
Description
Содержание Sierra M6-2
Страница 18: ...LeCroy Corporation Contents 16 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...
Страница 42: ...LeCroy Corporation Viewing Captured Data 40 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...
Страница 192: ...LeCroy Corporation Target and Device Emulation 190 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...
Страница 241: ...Sierra M6 2 SAS SATA Protocol Analyzer User Manual 239 Search LeCroy Corporation Figure 3 64 SAS Search Data Pattern ...
Страница 314: ...LeCroy Corporation Running Verification Script Engine VSE 312 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...
Страница 462: ...LeCroy Corporation Resetting the Toolbar 460 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...
Страница 468: ...LeCroy Corporation 466 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...