Sierra M6
‐
2 SAS/SATA Protocol Analyzer User Manual
131
Exercise and Capture
LeCroy Corporation
Frame
Length
Error
Check Frame Length Error and choose the type of error to introduce.
Code
violation
and
Disparity
error
Check these and specify DWORD offset and number of error DWORDs.
Additionally check:
No WTRM
Code Violation on SATA primitive
Disparity error on SATA primitive
Ignore XRDY/RRDY sequence
Delay in HOLD response (in sending HOLDA)
SOF,
EOF
and
CRC
errors
Check these and specify Double or Omit by checking the corresponding option button.
Insert
Primitive
Check Insert Primitive and then click the Type button to open the Primitive Type dialog
and select the primitive type.
Figure 2.129: Primitive Type Dialog
Click the down arrow on the Primitive combo box, choose a primitive, then click OK.
Fill
reserved
fields
with
Enter a value for which reserved fields to change, if other than 0.
Field
of
Frame
Select Destroy, scroll through the available choices in the Field of Frame list box, and
choose a field to destroy. Alternatively, select Specify Value to fill the chosen field with a
pre
‐
defined value.
Содержание Sierra M6-2
Страница 18: ...LeCroy Corporation Contents 16 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...
Страница 42: ...LeCroy Corporation Viewing Captured Data 40 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...
Страница 192: ...LeCroy Corporation Target and Device Emulation 190 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...
Страница 241: ...Sierra M6 2 SAS SATA Protocol Analyzer User Manual 239 Search LeCroy Corporation Figure 3 64 SAS Search Data Pattern ...
Страница 314: ...LeCroy Corporation Running Verification Script Engine VSE 312 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...
Страница 462: ...LeCroy Corporation Resetting the Toolbar 460 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...
Страница 468: ...LeCroy Corporation 466 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...