LeCroy Corporation
Exercise and Capture
130
Sierra M6
‐
2 SAS/SATA Protocol Analyzer User Manual
Affiliation
Setting
Check Clear Affiliation After Command Complete to release device to commands from
other sources, or check Leave Affiliation State Unchanged to retain control of device.
Enable
First
Burst
Check Enable First Burst to allow first burst.
Task
Attribute
Choose Simple, Head of Queue, Ordered, or ACA.
Outgoing ATA Frame Settings
Before selecting Outgoing Frame Settings, select the Types Of Frames and the Frame
Number on which to inject an error. Then check Outgoing Frame in the Generate Error On
area and then the enabled Settings button to display the Outgoing Frame Settings dialog.
Figure 2.128: Outgoing Frame Settings
Frame
Type
Error
Check this to introduce a frame type error.
Remove
Frame
from
sequence
Check this to remove frame from sequence.
Delay
in
sending
frame
Check this to delay sending frame and enter a value for the delay.
Содержание Sierra M6-2
Страница 18: ...LeCroy Corporation Contents 16 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...
Страница 42: ...LeCroy Corporation Viewing Captured Data 40 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...
Страница 192: ...LeCroy Corporation Target and Device Emulation 190 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...
Страница 241: ...Sierra M6 2 SAS SATA Protocol Analyzer User Manual 239 Search LeCroy Corporation Figure 3 64 SAS Search Data Pattern ...
Страница 314: ...LeCroy Corporation Running Verification Script Engine VSE 312 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...
Страница 462: ...LeCroy Corporation Resetting the Toolbar 460 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...
Страница 468: ...LeCroy Corporation 466 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...