12. VECTOR DISPLAY (VECT)
137
12.4.2 Selecting
a
Line
To select a line, follow the procedure below.
The selected line is indicated in the lower left of the display. If you press F•D 1, the selected
line changes to the first video line.
You can select a line when F•1 LINE SELECT is set to ON.
Changing this setting will also change the selected line in the picture, video signal
waveform, and status (data dump) displays.
Procedure
VECT (press and hold)
→
F•3 LINE SEL EXT REF
→
F•D 1 LINE VARIABLE
12.4.3
Setting the Line Selection Range
To set the line selection range, follow the procedure below.
The line selection range can be set when the input SDI signal is interlaced or segmented
frame.
Changing this setting will also change the picture display and video signal waveform
display line selection ranges.
Procedure
VECT (press and hold)
→
F•3 LINE SEL EXT REF
→
F•2 FIELD
Settings (the examples are for the setting ranges when the input format is set to
1080i/59.94)
FIELD1:
A line from field 1 can be selected. (Example: 1 to 563.)
FIELD2:
A line from field 2 can be selected. (Example: 564 to 1125.)
FRAME:
All lines can be selected. This is the default setting. (Example: 1 to 1125.)
12.4.4
Switching to an External Sync Signal
To switch to an external sync signal, follow the procedure below.
Changing this setting will also change the video signal waveform display and status display
sync signal settings.
When D_LINK FORMAT is set to YC10bit, you cannot use an external sync signal, and this
setting is not available.
[Reference] D_LINK
FORMAT
→
Section 5.1.4, “Setting the Input Format”
Procedure
VECT (press and hold)
→
F•3 LINE SEL EXT REF
→
F•4 EXT REF
Settings
ON:
An external sync signal is used.
OFF:
The internal sync signal is used. This is the default setting.