Disinfection / Cleaning
Part 1 • Page 12-23
Part 1 – Operating Instructions
Rev. 4.00 December 2014
Software version 1.04
EcoRO Dia I/II (HT)
Part 1 • Ch
apter 12
12.3.4 Cleaning (C) working steps
The EcoRO Dia I/II (HT) has a menu-guided cleaning program. The operator is guided step by step
through the program. Function and safety-related actions to be carried out by the operator are only
triggered after manual confirmation.
The cleaning times are set as described in
part 1, chapter 14.6 “Cleaning data, menu item 6”.
7/7
1.43321
Sodium Hydroxide, 30%
Other information
16 .
INCLUDING MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE, WITH RESPECT TO THE INFORMATION
HEREIN OR THE PRODUCT TO WHICH THE INFORMATION REFERS.
Cleaning is triggered by pressing the function key D/C in standby mode.
After this, select either “Disinfection” or “Cleaning”.
After cleaning (C) has been selected, this must be confirmed by pressing
the
-> 5s
key. Then the supply tank is emptied and filled again.
Cleaning must be started again by pressing the >
5s->
> key for
5 seconds.
After cleaning has been selected, the supply tank is emptied and filled
again.
Filling the cleaning agent
After the cleaning agent has been filled into the supply tank, the next
program step is initiated by pressing the “->” key.
Recirculation mode
In recirculation mode, the cleaning agent is guided through all the pipe
branches by triggering the valves (and pumps).
During recirculation mode, the remaining time in minutes is displayed.
Reaction mode
The purpose of reaction mode is to loosen the contamination. It automat-
ically follows recirculation mode according to time-related specifications
which can be programmed as detailed in
remaining time of reaction mode is displayed in minutes.
Please heed the concentration and reaction time specified by the
manufacturer of the cleaning agent!
Disinfection (DI)
C) Cleaning
D) Disinfection
Esc C D
Cleaning (C)
Start
Cleaning (C)
Esc
5s ->
Cleaning (C)
Filling tank
please wait ...
Esc
Cleaning (C)
Fill in cleaner
<<
Cleaning (C)
Recirculation mode
Time left ### min
<<
Cleaning (C)
Reaction time
Time left ### min.
<<