39
(2)
HEATER (DY-110H/220H/330H)
Exterior image
Specifications
- Rated 220V 1050W
How to inspect
-
Measure resistance at both ends of HEATER and, if resistance value is within 46.1Ω
±5%, it is normal
- Not suitable for use, if insulation resistance is below 100
㏁
(3)
Temperature Sensor (DY-110H/220H/330H)
Exterior image
Specifications
- Sensor element 503ET(49.12
㏀
±5% at 25
℃
)
How to inspect
- Measure resistance at both ends of temperature sensor and, if resistance value is
included in following:
61.46
㏀
±5% at 20
℃
49.12
㏀
±5% at 25
℃
3.3
㏀
±5% at 100
℃
it is normal, and, if it is below the above value, it is defective
Содержание DY-110H
Страница 1: ...1 MULTI PURPOSE DEHYDRATOR SERVICE MANUAL 2017 12 11...
Страница 6: ...6 2 CIRCUIT DIAGRAM DY 110H DY 220H...
Страница 7: ...7 DY 330H...
Страница 8: ...8 3 EXPLODED VIEW 1 DY 110H 2 DY 220H...
Страница 9: ...9 3 DY 330H...
Страница 10: ...10 4 CONTROL BOX ASSEMBLY DY 110H 5 CONTROL BOX ASS Y DY 220H...
Страница 11: ...11 6 CONTROL BOX ASSEMBLY DY 330H...
Страница 12: ...12 7 FAN COVER ASSEMBLY DY 110H 220H 330H 8 U COVER FRONT ASSEMBLY DY 110H...
Страница 13: ...13 9 U COVER FRONT ASSEMBLY DY 220H 10 U COVER FRONT ASSEMBLY DY 330H...
Страница 14: ...14 11 DOOR ASSEMBLY LF DY 220H 330H 12 DOOR ASSEMBLY RH DY 110H 220H 330H...
Страница 15: ...15 4 UNIT STRUCTURE 1 DY 110H...
Страница 16: ...16 2 DY 220H...
Страница 17: ...17 3 DY 330H...
Страница 38: ...38 POWER PCB...