28
b. Matured time goes into a changing mode or is cleared and 7-SEG flashes in a changing mode and, at this
time, setting temperature can be adjusted with temperature setting switch.
Order
Function
Range
Notes
1
Setting matured time
0 ~ 99 hours
(4) Dehydration specifications
①
Dehydration for red peppers
a. After pressing operation switch, select and push chili pepper button. When chili pepper switch is pressed,
60
℃
of temperature, 35 hours of remaining time, 7 hours of matured time are automatically set.
However, the set temperature, remaining time and matured time can be manually set by users.
b. When matured time is over during operation, ventilation starts by opening damper at 2
nd
stage and works
for the remaining time by lowering the current temperature by Delta T of red pepper.
c. After working for the set time, it stops heater and fan and notifies the end by making a beep sound for 2
minutes at 1 second intervals.
– If a timer is reset after completion, it restarts.
②
Normal hydration
a. Turning it on with operation switch.
b. Operating it by selecting the set temperature, remaining time and matured stage.
- Damper opens, depending on the set stage of moisture discharging
c. After working for the set time, it stops heater and fan and notifies the end by making a beep sound for 2
minutes at 1 second intervals.
– If a timer is reset after completion, it restarts.
③
Time delay in stopping fan
a. Fan is operated for 5 seconds more to remove post-heat at heater, when operation stops or timer ends,
besides fan error.
④
Damper operation
a. Opening, depending on the set stage, during operation.
(5) Model setting
①
Set each chamber with JP1 of MAIN PCB.
②
Set chamber 1 : JP1 OPEN
③
Set chamber 2 : 1,2 SHORT of JP1
④
Set chamber 3: SHORT 2,3 SHORT of JP1
7) HOW TO SET INTERNAL PARAMETER
■
DEHYDRATING ROOM
(1) How to access
Can be input, regardless of operation.
Pressing alarm off and operation switch at the same time for over 5 seconds.
- Accessing setting mode with beep sound
Working in following order, if remaining setting UP/DOWN is pressed.
Changing set value with matured time setting UP/DOWN.
Display(setting value)
Order
Содержание DY-110H
Страница 1: ...1 MULTI PURPOSE DEHYDRATOR SERVICE MANUAL 2017 12 11...
Страница 6: ...6 2 CIRCUIT DIAGRAM DY 110H DY 220H...
Страница 7: ...7 DY 330H...
Страница 8: ...8 3 EXPLODED VIEW 1 DY 110H 2 DY 220H...
Страница 9: ...9 3 DY 330H...
Страница 10: ...10 4 CONTROL BOX ASSEMBLY DY 110H 5 CONTROL BOX ASS Y DY 220H...
Страница 11: ...11 6 CONTROL BOX ASSEMBLY DY 330H...
Страница 12: ...12 7 FAN COVER ASSEMBLY DY 110H 220H 330H 8 U COVER FRONT ASSEMBLY DY 110H...
Страница 13: ...13 9 U COVER FRONT ASSEMBLY DY 220H 10 U COVER FRONT ASSEMBLY DY 330H...
Страница 14: ...14 11 DOOR ASSEMBLY LF DY 220H 330H 12 DOOR ASSEMBLY RH DY 110H 220H 330H...
Страница 15: ...15 4 UNIT STRUCTURE 1 DY 110H...
Страница 16: ...16 2 DY 220H...
Страница 17: ...17 3 DY 330H...
Страница 38: ...38 POWER PCB...