32
Problem
Cause
Resolution
Ground fault circuit
interrupter is OFF.
Circuit breaker
malfunctions.
a. Turn on circuit breaker.
Circuit breaker is faulty.
a. Check whether circuit breaker works by pressing
its reset(test) button.
b. If circuit breaker does not work, it is judged to be
faulty, thus, replace it with the same standardized
one.
Heater has a short.
a. Check insulation resistance with insulation
resistance tester.
b. If insulation resistance is below 50
㏁
, it is judged
that heater has a problem, thus, replace it with the
same standardized one.
Motor has a short.
a. Check insulation resistance with insulation-
resistance tester
b. If insulation resistance is below 50
㏁
, it is judged
that heater has a problem, thus, replace it with the
same standardized one.
Dehydrator
does
not operate
Check connection between
main PCB and DISPLAY
PCB.
a. Check whether there is a disconnection or cut
between PCB and PCB connection line.
Main PCB is faulty.
Replace main PCB.
DISPLAY PCB is faulty.
Replace display PCB.
Содержание DY-110H
Страница 1: ...1 MULTI PURPOSE DEHYDRATOR SERVICE MANUAL 2017 12 11...
Страница 6: ...6 2 CIRCUIT DIAGRAM DY 110H DY 220H...
Страница 7: ...7 DY 330H...
Страница 8: ...8 3 EXPLODED VIEW 1 DY 110H 2 DY 220H...
Страница 9: ...9 3 DY 330H...
Страница 10: ...10 4 CONTROL BOX ASSEMBLY DY 110H 5 CONTROL BOX ASS Y DY 220H...
Страница 11: ...11 6 CONTROL BOX ASSEMBLY DY 330H...
Страница 12: ...12 7 FAN COVER ASSEMBLY DY 110H 220H 330H 8 U COVER FRONT ASSEMBLY DY 110H...
Страница 13: ...13 9 U COVER FRONT ASSEMBLY DY 220H 10 U COVER FRONT ASSEMBLY DY 330H...
Страница 14: ...14 11 DOOR ASSEMBLY LF DY 220H 330H 12 DOOR ASSEMBLY RH DY 110H 220H 330H...
Страница 15: ...15 4 UNIT STRUCTURE 1 DY 110H...
Страница 16: ...16 2 DY 220H...
Страница 17: ...17 3 DY 330H...
Страница 38: ...38 POWER PCB...