24
■DY-330H
Code
Errors
Problem
Resolution
E1
Abnormally high
temp at left
chamber
Current temperature of left dehydrating
room is higher than set temperature over
15
℃
.
Do not lower set temperature rapidly than current
temperature over 15
℃
but gradually lower it.
If it happens every dehydration, the machine needs to
be examined.
E2
Abnormally high
temp at middle
chamber
Current temperature of middle dehydrating
room is higher than set temperature over
15
℃
.
E3
Abnormally high
temp at right
chamber
Current temperature of dehydrating room
chamber is higher than set temperature
over 15
℃
.
H1
Heater error at left
chamber
Heater of left dehydrating room is
abnormally applying an electric current.
For the first time, turn off the power and keep the
machine stable.
If it happens after re-operation, heater relay of
controller and heater need to be examined.
H2
Heater error at
middle chamber
Heater of middle dehydrating room is
abnormally applying an electric current.
H3
Heater error at
right chamber
Heater of right dehydrating room is
abnormally applying an electric current.
F1
Error at ventilation
of left chamber
Ventilation of left dehydrating room is not
working normally.
For the first time, turn off the power and keep the
machine stable.
If it happens after re-operation, blast motor and wing
need to be examined.
F2
Error at ventilation
of middle chamber
Ventilation of middle dehydrating room is
not working normally.
F3
Error at ventilation
of right chamber
Ventilation of right dehydrating room is not
working normally.
C1
Sensor error at left
chamber
Temperature sensor of left dehydrating
room is disconnected or shorted.
Check whether there is an error at sensor and
connection line.
C2
Sensor error at
middle chamber
Temperature sensor of middle dehydrating
room is disconnected or shorted.
C3
Sensor error at
right chamber
Temperature sensor of right dehydrating
room is disconnected or shorted.
Содержание DY-110H
Страница 1: ...1 MULTI PURPOSE DEHYDRATOR SERVICE MANUAL 2017 12 11...
Страница 6: ...6 2 CIRCUIT DIAGRAM DY 110H DY 220H...
Страница 7: ...7 DY 330H...
Страница 8: ...8 3 EXPLODED VIEW 1 DY 110H 2 DY 220H...
Страница 9: ...9 3 DY 330H...
Страница 10: ...10 4 CONTROL BOX ASSEMBLY DY 110H 5 CONTROL BOX ASS Y DY 220H...
Страница 11: ...11 6 CONTROL BOX ASSEMBLY DY 330H...
Страница 12: ...12 7 FAN COVER ASSEMBLY DY 110H 220H 330H 8 U COVER FRONT ASSEMBLY DY 110H...
Страница 13: ...13 9 U COVER FRONT ASSEMBLY DY 220H 10 U COVER FRONT ASSEMBLY DY 330H...
Страница 14: ...14 11 DOOR ASSEMBLY LF DY 220H 330H 12 DOOR ASSEMBLY RH DY 110H 220H 330H...
Страница 15: ...15 4 UNIT STRUCTURE 1 DY 110H...
Страница 16: ...16 2 DY 220H...
Страница 17: ...17 3 DY 330H...
Страница 38: ...38 POWER PCB...